| Electronic Components Datasheet Search |
|
ST72324J2 Datasheet(PDF) 159 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST72324J2 Datasheet(HTML) 159 Page - STMicroelectronics |
|
159 / 164 page ![]() ST72324Jx ST72324Kx 159/164 15 KNOWN LIMITATIONS 15.1 ALL DEVICES 15.1.1 External RC option The External RC clock source option described in previous datasheet revisions is no longer support- ed and has been removed from this specification. 15.1.2 CSS Function The Clock Security System function has been re- moved from the datasheet. 15.1.3 Safe Connection of OSC1/OSC2 Pins The OSC1 and/or OSC2 pins must not be left un- connected otherwise the ST7 main oscillator may start and, in this configuration, could generate an fOSC clock frequency in excess of the allowed maximum (>16MHz.), putting the ST7 in an un- safe/undefined state. Refer to Section 6.2 on page 24. 15.1.4 Unexpected Reset Fetch If an interrupt request occurs while a “POP CC” in- struction is executed, the interrupt controller does not recognise the source of the interrupt and, by default, passes the RESET vector address to the CPU. Workaround To solve this issue, a “POP CC” instruction must always be preceded by a “SIM” instruction. 15.1.5 Clearing active interrupts outside interrupt routine When an active interrupt request occurs at the same time as the related flag is being cleared, an unwanted reset may occur. Note: clearing the related interrupt mask will not generate an unwanted reset Concurrent interrupt context The symptom does not occur when the interrupts are handled normally, i.e. when: – The interrupt flag is cleared within its own inter- rupt routine – The interrupt flag is cleared within any interrupt routine – The interrupt flag is cleared in any part of the code while this interrupt is disabled If these conditions are not met, the symptom can be avoided by implementing the following se- quence: Perform SIM and RIM operation before and after resetting an active interrupt request. Example: SIM reset interrupt flag RIM Nested interrupt context: The symptom does not occur when the interrupts are handled normally, i.e. when: – The interrupt flag is cleared within its own inter- rupt routine – The interrupt flag is cleared within any interrupt routine with higher or identical priority level – The interrupt flag is cleared in any part of the code while this interrupt is disabled If these conditions are not met, the symptom can be avoided by implementing the following se- quence: PUSH CC SIM reset interrupt flag POP CC 15.1.6 External Interrupt Missed To avoid any risk of generating a parasitic inter- rupt, the edge detector is automatically disabled for one clock cycle during an access to either DDR and OR. Any input signal edge during this period will not be detected and will not generate an inter- rupt. This case can typically occur if the application re- freshes the port configuration registers at intervals during runtime. Workaround The workaround is based on software checking the level on the interrupt pin before and after writ- ing to the PxOR or PxDDR registers. If there is a level change (depending on the sensitivity pro- grammed for this pin) the interrupt routine is in- voked using the call instruction with three extra PUSH instructions before executing the interrupt routine (this is to make the call compatible with the IRET instruction at the end of the interrupt service routine). But detection of the level change does ensure that edge occurs during the critical 1 cycle duration and the interrupt has been missed. This may lead to occurrence of same interrupt twice (one hardware and another with software call). 1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |