3 / 10 page ![]() PM9102AP sames 3/10 Note 2: Isolation voltage may be specified, depending on customer requirements. CONNECTION DESCRIPTION Designation Description MAINS Voltage supply connection to Neutral line Voltage supply connection to Live line Neutral In Connection to positive side of current sensor Neutral Out Connection to negative side of current sensor JP1 SA9102/SA9602 output pin selector (Jumper) SK1 Power measurement output FUNCTIONAL DESCRIPTION 1. Power Calculation In the Application Circuit (Figure 2), the output current from the current sensor will be between 0 and 16µA (0 to 80A through a shunt resistor of 625µ S). The current input stage saturates at input currents greater than18µA RMS. The mains voltage (230V + 15% -20%) is used to supply the circuitry with power and for the power calculation, together with the current information from the current sensor (shunt resistor). The SA9102CP, SA9602EP (DIP-20), SA9602HP (DIP-20) and SA9602MP integrated circuits may be adjusted to accommodate any voltage or current values. The method of calculating external component values is described in paragraph 5 (Circuit Description). SAMES offers evaluation module options, namely 230V/80A and 115V/80A. The calculated power is integrated over time and converted into a corresponding frequency. The frequency is transmitted as a pulse rate through an opto-coupler. 2. Electrostatic Discharge (ESD) Protection The device's inputs/outputs are protected against ESD according to Mil-Std 883C, method 3015. The modules resistance to transients will be dependant upon the protection components used. 3. Power Consumption The overall power consumption rating for this power metering application (Figure 2), is under 500mW, excluding the current sensor, if a supply is taken directly from the mains. 4. Isolation The pulse output is isolated from the module, which is at mains potential, via an opto-coupler. (In the event of the use of a current transformer for current sensing, an opto-coupler would not be required.) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |