| Electronic Components Datasheet Search |
|
LC72710W Datasheet(PDF) 21 Page - Sanyo Semicon Device |
|
|
|||||||||||||||||||||||||||||
LC72710W Datasheet(HTML) 21 Page - Sanyo Semicon Device |
|
21 / 33 page ![]() No. 6166-21/33 LC72710W, 72710LW V DD voltage RST 3.4 V (2.5 V in the LC72710LW) V IL (0.3*VDD) V IH 300 ns (min) Notes on Operation during Resets and in Standby Mode Reset Signal The reset operation is executed when the supply voltage (VDD) rises above 3.4 V (2.5 V in the LC72710LW) and the RST pin input level is held at or below VIL for 300 ns or longer. (See the figure below.) When power is first applied, or when power is removed and applied again, always apply a reset before using this IC. Pin States during Reset Low level:CLK16 (5), DATA (6), FLOCK (7), BLOCK (8), FCK (9), BCK (10) High level: INT (33), RDY (16), CRC4 (11), DREQ (12) Open: D0 (17) to D15 (32), DO (36) Reset Operating Range The states of the output pins as the result of a reset signal are stipulated in the "Pin States during Reset" item above. The IC internal flip-flops are all reset. While the shift registers used for delay are also reset, the memory array is not influenced by this operation. However, since memory is not refreshed, data cannot be retained. The crystal oscillator circuit is not stopped. Post-Reset Data Input After a reset operation has completed, if at least one clock cycle (about 278 ns when the IC's main clock is 3.6 MHz) elapses, the register write circuit will be functional. (That is, the IC can accept data.) Notes on Standby Mode The IC is set to standby mode by applying a high level to the STNBY pin. Since all IC operations are stopped in this mode, the state is essentially equivalent to removing power from the IC. (Note that after clearing standby mode, applications must wait the oscillator stabilization time before using the IC.) The pin output states during standby mode are the same as those states during a reset as described above. The internal VICS registers are cleared and the status flag values are not retained. Output Conditions for Post-Error Correction Output (Default Mode) (1) For each block (272 bits) of received data, the IC applies (272, 190) code error correction and a layer 2 CRC error check. After the error correction has completed, the IC prepares to transfer the data to the CPU and outputs an interrupt signal from the INT pin. This is referred to as horizontal correction output. (2) Note that under the default operating conditions, this interrupt signal is not output unless the corresponding output data meets the following three conditions. • Error correction completed correctly and no errors were discovered in the layer 2 CRC check. • The data was received in both block and frame synchronization. • The data is packet data. (3) If the data could not be corrected in horizontal correction, product code correction is performed in frame units and a second horizontal correction operation is performed for this data that could not be corrected by the first horizontal correction. This sequence of operations is called vertical correction. The output conditions for data that can be acquired after vertical correction are as follows. • The data that could not be corrected by horizontal correction only, but that was corrected by vertical correction. • The data is packet data. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |