14 / 25 page ![]() KP236 Analog Absolute Pressure Sensor Functional Description Data Sheet 14 Revision 1.0, 2010-06-21 Note: Ratiometric signal error is not included in the overall accuracy. For error measurements, the supply voltage must have the nominal value ( V DD = VDD,Typ). The error band is determined by three continuous lines through four relevant breakpoints. Figure 5 Accuracy for pressure acquisition Table 4 Accuracy Temperature [°C] Error [kPa] Error Multiplier -40 ±2.0 2.0 0 ±1.0 1.0 85 ±1.0 1.0 125 ±2.0 2.0 -40 0 85 125 temperature [°C] 0.0 0.5 1.5 1.0 2.0 2.5 1.0 2.0 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|