13 / 57 page ![]() 90E21/22/23/24 SINGLE-PHASE HIGH-PERFORMANCE WIDE-SPAN ENERGY METERING IC Functional Description 13 January 10, 2012 3.4 N LINE METERING AND ANTI-TAMPERING 3.4.1 METERING MODE AND L/N LINE CURRENT SAMPLING GAIN CONFIGURATION The 90E23 and 90E24 have two current sampling circuits with N line metering and anti-tampering functions. The MMD1 and MMD0 pins are used to configure the metering mode. Refer to Table-7. The 90E23 and 90E24 have two current sampling circuits with differ- ent gain configurations. L line gain can be 1, 4, 8, 16 and 24, and N line gain can be 1, 2 and 4. The configuration is made by the MMode register (2BH). Generally L line can be sampled over shunt resistor or CT. N line can be sampled over CT for isolation consideration. Note that Rogowski coil is not supported. 3.4.2 ANTI-TAMPERING MODE Threshold In anti-tampering mode, the power difference threshold between L line and N line can be: 1%, 2%,... 12%, 12.5%, 6.25%, 3.125% and 1.5625%, altogether 16 choices. The configuration is made by the Pthresh[3:0] bits (MMode, 2BH) and the default value is 3.125%. The threshold is applicable for active energy. The metering line of the reac- tive energy follows that of the active energy. Compare Method In anti-tampering mode, the compare method is as follows: If current metering line is L line and N line is switched as the metering line, otherwise L line keeps as the metering line. If current metering line is N line and L line is switched as the metering line, otherwise N line keeps as the metering line. This method can achieve hysteresis around the threshold automati- cally. L line is employed after reset by default. Special Treatment at Low Power When power is low, general factors such as the quantization error or calibration difference between L line and N line might cause the power difference to be exceeded. To ensure L line and N line to start up nor- mally, special treatment as follows is adopted: The line with higher power is selected as the metering line when both L line and N line power are lower than 8 times of the startup power but higher than the startup power. Table-7 Metering Mode MMD1 MMD0 Metering Mode CFx (CF1 or CF2) Output 00 Anti-tampering Mode (larger power) CFx represents the larger energy line. Refer to section 3.4.2. 0 1 L Line Mode (fixed L line) CFx represents L line energy all the time. 10 L+N Mode (applicable for single-phase three-wire system) CFx represents the arithmetic sum of L line and N line energy 11 Flexible Mode (line speci- fied by the LNSel bit (MMode, 2BH)) CFx represents energy of the specified line. Threshold 100% * Power Active Line L Power Active Line L - Power Active Line N > Threshold 100% * Power Active Line N Power Active Line N - Power Active Line L > |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |