| Electronic Components Datasheet Search |
|
LPF-16 Datasheet(PDF) 1 Page - Mean Well Enterprises Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
LPF-16 Datasheet(HTML) 1 Page - Mean Well Enterprises Co., Ltd. |
|
1 / 3 page ![]() SPECIFICATION MODEL DCVOLTAGE RATEDCURRENT RATEDPOWER OUTPUT LINEREGULATION LOADREGULATION SETUP,RISETIME Note.6 HOLDUP TIME (Typ.) VOLTAGERANGE Note.5 FREQUENCY RANGE POWERFACTOR (Typ.) EFFICIENCY (Typ.) ACCURRENT INPUT INRUSHCURRENT(Typ.) LEAKAGECURRENT WORKINGTEMP. WORKINGHUMIDITY STORAGETEMP.,HUMIDITY TEMP.COEFFICIENT VIBRATION MTBF DIMENSION OTHERS NOTE PACKING OVERCURRENT Note.4 OVERVOLTAGE 12V LPF-16-12 LPF-16-15 LPF-16-20 LPF-16-24 LPF-16-30 LPF-16-36 LPF-16-42 LPF-16-48 LPF-16-54 6~12V 15V 7.5~15V 20V 10~20V 24V 12~24V 30V 15~30V 36V 18~36V 48V 24~48V 1.34A 1.07A 0.8A 0.67A 0.54A 0.45A 0.34A 16.08W 16.05W 16W 16.08W 16.2W 16.2W 16.32W 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 250mVp-p 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 2.0% 1.5% 1.0% 0.5% 0.5% 0.5% 0.5% 1500ms,80ms/115VACatfullload1500ms,80ms/230VAC 16ms atfullload230VAC/115VAC 90~305VAC127~431VDC 47~63Hz 84% 84% 86% 86% 86% 86% 86% COLDSTART 50A/230VAC <0.75mA /240VAC 95~108% Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved 20~95%RH non-condensing -40~+80 ,10~95%RH 0.03%/ (0~50 ) 10~500Hz,2G12min./1cycle,periodfor72min.eachalongX, Y,Zaxes 473.3Khrsmin.MIL-HDBK-217F(25 ) 148*40*32mm(L*W*H) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 0.21Kg;40pcs/9.4Kg/1.02CUFT Protectiontype: Shutdownandlatchoffo/pvoltage,re-powerontorecover RIPPLE&NOISE(max.) Note.2 VOLTAGETOLERANCE Note.3 ENVIRONMENT SAFETY & EMC PROTECTION SHORTCIRCUIT Hiccupmode,recoversautomaticallyafterfaultconditionisremoved. UL8750,CSA C22.2No.250.0-08(exceptfor48V,54V),EN61347-1,EN61347-2-13independentapproved,IP67(optional);DesignrefertoUL60950-1, TUVEN60950-1 54V 27~54V 0.3A 16.2W 350mVp-p 4.0% 0.5% 0.5% 42V 21~42V 0.39A 16.38W 250mVp-p 4.0% 0.5% 0.5% 86% 86% 15~18V 17.5~21V 23~27V 28~35V 34~40V 41~49V 54~63V 0.4A /115VAC0.2A /230VAC 46~54V 59~66V FileName:LPF-16-SPEC 2011-12-21 16WSingleOutputSwitchingPowerSupply Universal AC input / Full range Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function Cooling by free air convection Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting 3 years warranty (up to 305VAC) Suitable for dry / damp locations(wet location for ) Fully isolated plastic case Class power unit, no FG Class 2 power unit IP67(optional , model NO. : LPF-16-12 P) LPF-16-12 P Features : L P F - 1 6 series ISOLATIONRESISTANCE CONSTANTCURRENTREGION Note.4 SAFETY STANDARDS WITHSTANDVOLTAGE I/P-O/P:3.75KVAC I/P-O/P:100MOhms/500VDC/25 /70%RH F M M 110 SELV OVERTEMPERATURE 100J Ó5J( TSW1)DetectonU2 Protectiontype:Shutdowno/pvoltage,recoverautomaticallyaftertemperaturegoesdown EMCIMMUNITY CompliancetoEN55015;EN61000-3-2ClassC( 50%load);EN61000-3-3 EMCEMISSION PF>0.97/115VAC,PF>0.95/230VAC,PF>0.92/277VACatfullload(Pleasereferto"PowerFactorCharacteristic"curve) -40~+70 (Referto"DeratingCurve") CompliancetoEN61000-4-2,3,4,5,6,8,11;EN61547,lightindustrylevel(surge2KV),criteria A ( except for 48V,54V ) ( for 48V,54V only) |
Similar Part No. - LPF-16 |
|
Similar Description - LPF-16 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |