| Electronic Components Datasheet Search |
|
AWHW10G-0202-T-R Datasheet(PDF) 13 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AWHW10G-0202-T-R Datasheet(HTML) 13 Page - Texas Instruments |
|
13 / 49 page ![]() EVM Configuration Using the Fusion GUI www.ti.com 5 EVM Configuration Using the Fusion GUI The TPS40422 on this EVM leaves the factory pre-configured. See Table 3 for a short list of key factory configuration parameters as obtained from the configuration file. Table 3. Key Factory Configuration Parameters Address Hex Address Dec Part ID 0x1B 27 TPS40422 General Cmd ID With Phase Cmd Code Hex Encoded Hex Decoded Numeric Comments VIN_OFF 0x36 0xF014 5.00 V 5 Turn OFF voltage VIN_ON 0x35 0xF01C 7.00 V 7 Turn ON voltage Vout 1 Comments IOUT_CAL_GAIN 0x38 0x8821 1.0071 m Ω 1.0071 DCR of output inductor IOUT_CAL_OFFSET 0x39 0xE000 0.0000 A 0 Current offset for GUI readout IOUT_OC_FAULT_LIMIT 0x46 0xF83C 30.0 A 30 OC fault level IOUT_OC_FAULT_RESPONSE 0x47 0x3C Restart Continuously Response to OC fault IOUT_OC_WARN_LIMIT 0x4A 0xF832 25.0 A 25 OC warning level MFR_04 (VREF_TRIM) 0xD4 0x0000 0.000 V 0 Trim voltage Control signal and OPERATION command ON_OFF_CONFIG 0x02 0x02 Mode: Always Converting not required Unit: Immediate Off; Margin: OPERATION 0x01 0x00 Response to turn OFF trigger None OT_FAULT_LIMIT 0x4F 0x007D 125 C 125 OT fault level OT_WARN_LIMIT 0x51 0x0064 100 C 100 OT warn level TON_RISE 0x61 0xE02B 2.6875 ms 2.6875 Soft-start time Vout 2 Comments IOUT_CAL_GAIN 0x38 0x8821 1.0071 m Ω 1.0071 DCR of output inductor IOUT_CAL_OFFSET 0x39 0xE000 0.0000 A 0 Current offset for GUI readout IOUT_OC_FAULT_LIMIT 0x46 0xF832 25.0 A 25 OC fault level IOUT_OC_FAULT_RESPONSE 0x47 0x3C Restart Continuously Response to OC fault IOUT_OC_WARN_LIMIT 0x4A 0xF828 20.0 A 20 OC warning level MFR_04 (VREF_TRIM) 0xD4 0x0000 0.000 V 0 Trim voltage Control signal and OPERATION command ON_OFF_CONFIG 0x02 0x02 Mode: Always Converting not required Unit: Immediate Off; Margin: OPERATION 0x01 0x00 Response to turn OFF trigger None OT_FAULT_LIMIT 0x4F 0x007D 125 C 125 OT fault level OT_WARN_LIMIT 0x51 0x0064 100 C 100 OT warn level TON_RISE 0x61 0xE02B 2.6875 ms 2.6875 Soft-start time If it is desired to configure the EVM to settings other than the factory settings shown in Table 3, the TI Fusion Digital Power Designer software can be used for reconfiguration. It is necessary to have input voltage applied to the EVM prior to launching the software so that the TPS40422 may respond to the GUI and the GUI can recognize the TPS40422. The default configuration for the EVM is to start converting at an input voltage of 7 V; therefore, to avoid any converter activity during configuration, an input voltage less than 7 V must be applied. An input voltage of 5 V is recommended. 5.1 Configuration Procedure 1. Adjust the input supply to provide 5 Vdc, current limited to 1 A. 2. Apply the input voltage to the EVM. See Figure 2 and Figure 3 for connections and test setup. 3. Launch the Fusion GUI software. See the screen shots in Section 10 for more information. 4. Configure the EVM operating parameters as desired. 14 Using the PWR091EVM Dual-Output DC/DC Analog With PMBus Interface SLVU638 – January 2012 Submit Documentation Feedback Copyright © 2012, Texas Instruments Incorporated |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |