Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

CLVCH16652AIDGGREP Datasheet(PDF) 2 Page - Texas Instruments

Part # CLVCH16652AIDGGREP
Description  16-BIT BUS TRANSCEIVER AND REGISTER WITH 3-STATE OUTPUTS
PDF  13 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI1 [Texas Instruments]
Direct Link  http://www.ti.com
Logo TI1 - Texas Instruments

CLVCH16652AIDGGREP Datasheet(HTML) 2 Page - Texas Instruments

  CLVCH16652AIDGGREP Datasheet HTML 1Page - Texas Instruments CLVCH16652AIDGGREP Datasheet HTML 2Page - Texas Instruments CLVCH16652AIDGGREP Datasheet HTML 3Page - Texas Instruments CLVCH16652AIDGGREP Datasheet HTML 4Page - Texas Instruments CLVCH16652AIDGGREP Datasheet HTML 5Page - Texas Instruments CLVCH16652AIDGGREP Datasheet HTML 6Page - Texas Instruments CLVCH16652AIDGGREP Datasheet HTML 7Page - Texas Instruments CLVCH16652AIDGGREP Datasheet HTML 8Page - Texas Instruments CLVCH16652AIDGGREP Datasheet HTML 9Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 13 page
background image
www.ti.com
DESCRIPTION/ORDERING INFORMATION (CONTINUED)
SN74LVCH16652A-EP
16-BIT BUS TRANSCEIVER AND REGISTER
WITH 3-STATE OUTPUTS
SCAS743A – DECEMBER 2003 – REVISED AUGUST 2005
Complementary output-enable (OEAB and OEBA) inputs control the transceiver functions. Select-control (SAB
and SBA) inputs select whether real-time or stored data is transferred. A low input level selects real-time data,
and a high input level selects stored data. The circuitry used for select control eliminates the typical decoding
glitch that occurs in a multiplexer during the transition between stored and real-time data. Figure 1 illustrates the
four fundamental bus-management functions that can be performed with the SN74LVCH16652A.
Data on the A or B bus, or both, can be stored in the internal D flip-flops by low-to-high transitions at the
appropriate clock (CLKAB or CLKBA) inputs, regardless of the levels on the select-control or output-enable
inputs. When SAB and SBA are in the real-time transfer mode, it also is possible to store data without using the
internal D-type flip-flops by simultaneously enabling OEAB and OEBA. In this configuration, each output
reinforces its input. When all other data sources to the two sets of bus lines are at high impedance, each set of
bus lines remains at its last-level configuration.
To ensure the high-impedance state during power up or power down, OEBA should be tied to VCC through a
pullup resistor and OEAB should be tied to GND through a pulldown resistor; the minimum value of the resistor is
determined by the current-sinking/current-sourcing capability of the driver.
Inputs can be driven from either 3.3-V or 5-V devices. This feature allows the use of these devices as translators
in a mixed 3.3-V/5-V system environment.
Active bus-hold circuitry is provided to hold unused or floating data inputs at a valid logic level. Use of pullup or
pulldown resistors with the bus-hold circuitry is not recommended. The bus-hold circuitry is part of the input
circuit and is not disabled by OE or DIR.
ORDERING INFORMATION
TA
PACKAGE(1)
ORDERABLE PART NUMBER
TOP-SIDE MARKING
–40
°C to 85°C
TSSOP – DGG
Tape and reel
CLVCH16652AIDGGREP
CH16652AEP
(1)
Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at
www.ti.com/sc/package.
FUNCTION TABLE
INPUTS
DATA I/O(1)
OPERATION OR FUNCTION
OEAB
OEBA
CLKAB
CLKBA
SAB
SBA
A1–A8
B1–B8
L
H
H or L
H or L
X
X
Input
Input
Isolation
L
H
↑
↑
X
X
Input
Input
Store A and B data
X
H
↑
H or L
X
X
Input
Unspecified(2)
Store A, hold B
H
H
↑
↑
X(2)
X
Input
Output
Store A in both registers
L
X
H or L
↑
X
X
Unspecified(2)
Input
Hold A, store B
L
L
↑
↑
X
X(2)
Output
Input
Store B in both registers
L
L
X
X
X
L
Output
Input
Real-time B data to A bus
L
L
X
H or L
X
H
Output
Input
Stored B data to A bus
H
H
X
X
L
X
Input
Output
Real-time A data to B bus
H
H
H or L
X
H
X
Input
Output
Stored A data to B bus
Stored A data to B bus and
H
L
H or L
H or L
H
H
Output
Output
stored B data to A bus
(1)
The data-output functions can be enabled or disabled by a variety of level combinations at OEAB or OEBA. Data-input functions always
are enabled; i.e., data at the bus terminals is stored on every low-to-high transition of the clock inputs.
(2)
Select control = L, clocks can occur simultaneously. Select control = H, clocks must be staggered to load both registers.
2



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com