4 / 10 page ![]() MPX5010 SERIES 4 Motorola Sensor Device Data Transfer Function (MPX5010D) Nominal Transfer Value: Vout = VS x (0.09 x P + 0.04) Nominal Transfer Value: ± (Pressure Error x Temp. Factor x 0.09 x VS) Nominal Transfer Value: VS = 5.0 V ± 0.25 Vdc Temperature Error Band Temp Multiplier – 40 3 0 to 85 1 +125 3 Temperature in C ° 4.0 3.0 2.0 0.0 1.0 –40 –20 0 20 40 60 140 120 100 80 MPX5010D Series Temperature Error Factor Pressure Error Band NOTE: The Temperature Multiplier is a linear response from 0 ° to –40°C and from 85° to 125°C. Pressure (kPa) 0.5 0.4 0.2 –0.3 –0.4 –0.5 0 12 3 456 7 Pressure Error (Max) 0 to 10 kPa ± 0.5 kPa 89 0 0.3 0.1 –0.2 –0.1 10 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|