3 / 9 page ![]() 194 Multiple Limit Switch VB Specifications ■ Approved Standards Note: Ground terminal models only. ■ Approved Standard Ratings TÜV (EN60947-5-1) (Only Ground Terminal Models are Approved) Standard Load Micro Load CCC (GB14048.5) ■ General Ratings Standard Load Note: The above currents are steady-state currents. Micro Load Ratings ■ Characteristics Note: 1. The above values are initial values. 2. The values are calculated at an operating temperature of 5 °C to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments. Agency Standards File No. Approved models TÜV Rheinland EN60947-5-1 (IEC947-5-1) R9551017 Only models with ground terminals CCC (CQC) GB14048.5 2003010305077628 Ask your OMRON representative for infor- mation on approved models. Applicable category and ratings AC-15 2 A/250 VAC DC-12 2 A/48 VDC Applicable category and ratings AC-14 0.1 A/125 VAC DC-12 0.1 A/30 VDC Applicable category and ratings AC-15 2 A/250 VAC Rated voltage Resistive load Inrush current Inrush current NC NO NC NO 125 VAC 10 A 24 A max. 250 VAC 10 A 125 VDC 0.6 A 250 VDC 0.3 A Rated voltage Resistive load 125 VAC 0.1 A 8 VDC 0.1 A 30 VDC 0.1 A Degree of protection IP67 Durability (See note 2.) Mechanical: 5,000,000 operations min. Electrical: 300,000 operations min. (10 A at 250 VAC, resistive load) Operating speed 0.1 mm to 0.5 m/s Operating frequency Mechanical: 120 operations min. Electrical: 30 operations min. Rated frequency 50/60 Hz (AC) Insulation resistance 100 M Ω min. (at 500 VDC) Contact resistance 15 m Ω max. (initial value) Dielectric strength 1,000 VAC/U imp 4,000 VAC between terminals of same polarity 1,500 VAC/U imp 4,000 VAC between current-carrying metal parts and ground 1,500 VAC/U imp 4,000 VAC between each terminal and non-current-carrying metal part U imp 4 kV (EN60947-5-1) between terminals of different polarity Rated insulation voltage (U i) 300 VAC (EN60947-5-1) Switching overvoltage 1,000 V max. (EN60947-5-1) Pollution degree (operating environment) 3 (EN60947-5-1) Short-circuit protective device (SCPD) 10 A fuse type gG or gI (IEC269) Conditional short-circuit current 100 A (EN60947-5-1) Conventional enclosed thermal current (I the) 5 A, 0.5 A (EN60947-5-1) Protection against electric shock Insulation class I (Use the grounding terminal or ground on the machine side.) Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Destruction: 1,000 m/s2 min. Malfunction: 200 m/s2 min. Ambient temperature Operating: –10 °C to 80°C (with no icing) Ambient humidity Operating: 35% to 95% Weight Approx. 580 g (in the case of VB-4211) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |