Back Button AIC1803CCS Datasheet HTML 4Page - Analog Intergrations Corporation AIC1803CCS Datasheet HTML 5Page - Analog Intergrations Corporation AIC1803CCS Datasheet HTML 6Page - Analog Intergrations Corporation AIC1803CCS Datasheet HTML 7Page - Analog Intergrations Corporation AIC1803CCS Datasheet HTML 8Page - Analog Intergrations Corporation AIC1803CCS Datasheet HTML 9Page - Analog Intergrations Corporation AIC1803CCS Datasheet HTML 10Page - Analog Intergrations Corporation AIC1803CCS Datasheet HTML 11Page - Analog Intergrations Corporation AIC1803CCS Datasheet HTML 12Page - Analog Intergrations Corporation  
Zoom Inzoom in Zoom Outzoom out
 9 / 12 page
background image
AIC1803
9
beyond the overdischarge delay time (T
OD) period,
discharging is inhibited by the turning-off of the
discharge
control
MOSFET
M1.
The
overdischarge delay time is set by the external
capacitor
C
TD.
Inhibition
of
discharging
is
immediately released when the voltage of the
overdischarge
cell
becomes
higher
than
the
overdischarge
release
voltage
(V
ODR)
through
charging.
Overcurrent Protection
In normal
mode,
the
AIC1803
continuously
monitors the discharge current by sensing the
voltage of CS pin. If the voltage V
CC-VCS exceeds
the overcurrent protection voltage (VOIP) beyond
the
overcurrent
delay
time
(TOI) period, the
overcurrent
protection
circuit
operates
and
discharging is inhibited by the turning-off of the
discharge control MOSFET M1. Discharging must
be inhibited for at least 256mS after overcurrent
takes place to avoid damage to external control
MOSFETs due to rapidly switching transient
between
BATT+
and
BATT-
terminals.
The
overcurrent condition returns to normal mode
when the load is released and the
impedance
between the BATT+ and BATT- terminals is
20M
Ω or higher.
The
AIC1803
is
provided
with
the
three
overcurrent detection levels (0.15V, 0.3V and
1.0V) and the three overcurrent delay time (T
OI1,
T
OI2 and TOI3) corresponding to each overcurrent
detection level. T
OI1 is set by the external capacitor
C
TI.
T
OI2
and T
OI3
default to 4mS and 300
µs
respectively, and can not be adjusted due to
protection of external MOSFETs
Cell-Balancing
Bleeding
after
Overcharge
When either of the battery cells is overcharged,
the AIC1803 provides the cell-balancing bleeding
function to discharge the overcharged cell at
about 9mA until the voltage of the overcharged
cell decreases to overcharge release voltage
(V
OCR or VOCP-vHYS ). This function is accomplished
by connecting UD1, UD2, UD3 pins to the positive
terminals of battery cells BAT1, BAT2, BAT3
respectively.
The
bleeding
current
can
be
decreased by inserting resistors along UD1 pin to
BAT1 positive terminal path and UD3 pin to BAT3
positive terminal path.
Power-Down after Overdischarge
When overdischarge occurs, the AIC1803 will go
into power-down mode, turning off all the timing
generation and detection circuitry to reduce the
quiescent current to about 1.3
µA (V
CC=6.9V). In
the unusual case where one battery cell is
overdischarged
while
another
one
under
overcharge condition, the AIC1803 will turn off all
the detection circuitry except the overcharge
detection circuit for the cell under overcharge
condition.
Charge Detection after Overdischarge
When overdischarge occurs, the discharge control
MOSFET M1 turns off and discharging is inhibited.
However, charging is still permitted through the
parasitic diode of M1. Once the charger is
connected to the battery pack, the AIC1803
immediately turns on all the timing generation and
detection circuitry and goes into normal mode.
Charging is determined to be in progress if the CS
pin voltage is higher than VCC + 0.4V (charge
detection threshold voltage V
CH).
DESIGN GUIDE
Setting
the
Overcharge
and
Overdischarge Delay Time
The overcharge delay time is set by the external
capacitor C
TC and the overdischarge delay time is
set by the external capacitor C
TD. The relationship
between capacitance of the external capacitors
and delay time is tabulated as below.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com