Back Button TPIC84000TPWPRQ1 Datasheet HTML 8Page - Texas Instruments TPIC84000TPWPRQ1 Datasheet HTML 9Page - Texas Instruments TPIC84000TPWPRQ1 Datasheet HTML 10Page - Texas Instruments TPIC84000TPWPRQ1 Datasheet HTML 11Page - Texas Instruments TPIC84000TPWPRQ1 Datasheet HTML 12Page - Texas Instruments TPIC84000TPWPRQ1 Datasheet HTML 13Page - Texas Instruments TPIC84000TPWPRQ1 Datasheet HTML 14Page - Texas Instruments TPIC84000TPWPRQ1 Datasheet HTML 15Page - Texas Instruments TPIC84000TPWPRQ1 Datasheet HTML 16Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 12 / 29 page
background image
TPIC84125-Q1
SLDS175 – AUGUST 2010
www.ti.com
Basic Commands and Data Structure
Table 2. Commands
COMMAND
COMMAND DESCRIPTION
DATA SENT ON SDO AT NEXT FALLING EDGE OF NCS
MSB....LSB
0xxx xxxx
Read back the programmed register.
Programmed register
Programmed register will be loaded into SPI register at next
falling edge of NCS.
1xxx xxxx
Request control and status register.
Control and status register
The control and status register will be loaded into SPI
register at next falling edge of NCS.
1000 xxxx
No operation only feedback. Data bits are unused. The
Control and status register
x110 xxxx
control and status register will be loaded into SPI register at
x111 xxxx
next falling edge of NCS.
0000 xxxx
No operation only feedback.
All bits '0'
x001 xxxx
Program configuration register. Data bits contain data for
Programmed register or control and status register
configuration register.
depending on MSB
x010 xxxx
Program control and status register. Data bits contain data
Control and status register whatever is the MSB
for control and status register.
x011 xxxx
Program data buffer1. Data bits contain data for buffer1.
Programmed register or control and status register
depending to MSB
x100 xxxx
Program data buffer2. Data bits contain data for buffer2.
Programmed register or control and status register
depending to MSB
x101 xxxx
Start transmission. Data bits are unused. (When not in
Control and status register
automode)
The command that is sent out on SDO is the command that was sent on SDI at the previous cycle. The fifth MSB
bit is a failure bit which is set to '1' by the device when one of the following failures occurs: over temperature,
temperature pre-warning, under voltage at VS or VD, output over-current. Default is '0' for this bit then value is
latched until is read by SPI. This bit is the same as bit 18 in Control and Status register.
Figure 7. Format for 64 Bits Returned on SDO
12
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s): TPIC84125-Q1



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com