| Electronic Components Datasheet Search |
|
MB4000RU Datasheet(PDF) 2 Page - MicroPower Direct, LLC |
|
|
|||||||||||||||||||||||||||||
MB4000RU Datasheet(HTML) 2 Page - MicroPower Direct, LLC |
|
2 / 4 page ![]() Model Selection Guide 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com www.micropowerdirect.com Notes: 1. Start up time is measured at nominal input and with a constant resistive load. 2. Load regulation is specified for a load change of minimum load to full load. 3. Cross regulation is measured with the output being tested at 100% load.The second output is varied from 25% to 100% load. 4. When measuring output ripple, it is recommended that an external 1 µF capacitor and 10 µF capacitor be connected in parallel from the +VOUT to the -VOUT pins for single output units and from each output to common for dual output units. 5. Transient recovery is measured to within a 1% error band for a load step change of 25%. 6. Short circuit protection is provided by a “hiccup mode” circuit. 7. The switching frequency for 24 VDC output models is 285 kHz. 8. Operation at no-load will not damage these units. However, they may not meet all specifications if operated below the specified minimum load. 9. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Model Number Input Output Efficiency (%, Typ) Over Voltage Protection (VDC Typ) Capacitive Load (µF, Max) Fuse Rating Slow-Blow (A) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min) Nominal Range Full-Load No-Load MB4024S-03RU 24 9.0 - 36.0 1,240 90 3.3 8,000 0 89 3.9 21,000 8.0 MB4024S-05RU 24 9.0 - 36.0 1,850 90 5.0 8,000 0 90 6.2 13,600 8.0 MB4024S-12RU 24 9.0 - 36.0 1,870 95 12.0 3,330 0 89 15.0 2,400 8.0 MB4024S-15RU 24 9.0 - 36.0 1,870 105 15.0 2,670 0 89 18.0 1,500 8.0 MB4024S-24RU 24 9.0 - 36.0 1,835 115 24.0 1,670 0 91 30.0 600 8.0 MB4024D-12RU 24 9.0 - 36.0 1,890 65 ±12.0 ±1,670 ±145 88 ±15.0 ±1,200 8.0 MB4024D-15RU 24 9.0 - 36.0 1,890 65 ±15.0 ±1,330 ±110 88 ±18.0 ±750 8.0 MB4048S-03RU 48 18.0 - 75.0 620 55 3.3 8,000 0 89 3.9 21,000 4.0 MB4048S-05RU 48 18.0 - 75.0 930 55 5.0 8,000 0 90 6.2 13,600 4.0 MB4048S-12RU 48 18.0 - 75.0 930 60 12.0 3,330 0 90 15.0 2,400 4.0 MB4048S-15RU 48 18.0 - 75.0 930 65 15.0 2,670 0 90 18.0 1,500 4.0 MB4048S-24RU 48 18.0 - 75.0 918 75 24.0 1,670 0 91 30.0 600 4.0 MB4048D-12RU 48 18.0 - 75.0 950 45 ±12.0 ±1,670 ±145 88 ±15.0 ±1,200 4.0 MB4048D-15RU 48 18.0 - 75.0 950 45 ±15.0 ±1,330 ±110 88 ±18.0 ±750 4.0 On single output units, an external resister may be added to adjust the converter output. To adjust the output UP, connect a 5%, 3W resistor between the minus output pin (5) and the Vout trim pin (6). To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin (4) and the Vout trim pin (6). The trim table at right gives suggested resistor values for this adjustment. External Trim Remote On/Off MB40xxS-03RU Trim Down Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts RDOWN 72.61 32.55 19.20 12.52 8.51 5.84 3.94 2.51 1.39 0.50 k Trim Up Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts RUP 60.84 27.40 16.25 10.68 7.34 5.11 3.51 2.32 1.39 0.65 k MB40xxS-05RU Trim Down Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts RDOWN 138.88 62.41 36.92 24.18 16.53 11.44 7.79 5.06 2.94 1.24 k Trim Up Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts RUP 106.87 47.76 28.06 18.21 12.30 8.36 5.55 3.44 1.79 0.48 k MB40xxS-12RU Trim Down Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts RDOWN 413.55 184.55 108.22 70.05 47.15 31.88 20.98 12.80 6.44 1.35 k Trim Up Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts RUP 351.00 157.50 93.00 60.75 41.40 28.50 19.29 12.37 7.00 2.70 k MB40xxS-15RU Trim Down Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts RDOWN 530.73 238.61 141.24 92.56 63.35 43.87 29.96 19.53 11.41 4.92 k Trim Up Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts RUP 422.77 189.89 112.26 73.44 50.15 34.63 23.54 15.22 8.75 3.58 k MB40xxS-24RU Trim Down Vout VO x 0.99 VO x 0.98 VO x 0.97 VO x 0.96 VO x 0.95 VO x 0.94 VO x 0.93 VO x 0.92 VO x 0.91 VO x 0.90 Volts RDOWN 333.39 148.80 87.26 56.50 38.04 25.73 16.94 10.35 5.22 1.12 k Trim Up Vout VO x 1.01 VO x 1.02 VO x 1.03 VO x 1.04 VO x 1.05 VO x 1.06 VO x 1.07 VO x 1.08 VO x 1.09 VO x 1.10 Volts RUP 243.70 108.50 63.43 40.90 27.38 18.37 11.93 7.10 3.34 0.34 k Applying a signal to pin 3 will turn the unit ON/OFF. If the pin is left open, the unit operates. If grounded, the unit will shut off. The specifications for the ON/OFF function are: Parameter Min Typ Max Units Supply On 3.5 12.0 VDC Supply Off 0.0 1.2 VDC Standby Input Current 2.5 mA Control Common Referenced to Negative Input (pin 2) Control Input Current (ON) 0.5 mA Control Input Current (OFF) -0.5 mA For heatsink option, add suffix “H” to model number (i.e. MB4024S-15RU-H) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |