| Electronic Components Datasheet Search |
|
ADS1217IPFBT Datasheet(PDF) 13 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
ADS1217IPFBT Datasheet(HTML) 13 Page - Texas Instruments |
|
13 / 34 page ![]() ADS1217 SBAS260C 13 www.ti.com VOLTAGE REFERENCE INPUT The ADS1217 uses a differential voltage reference input. The input signal is measured against the differential voltage VREF ≡ (VREF+) – (VREF–). For AVDD = 5V, VREF is typically 2.5V. For AVDD = 3V, VREF is typically 1.25V. Due to the sampling nature of the modulator, the reference input current increases with higher modulator clock frequency (fMOD) and higher PGA settings. ON-CHIP VOLTAGE REFERENCE A selectable voltage reference (1.25V or 2.5V) is available for supplying the voltage reference input. To use, connect VREF– to AGND and VREF+ to VREFOUT. The enabling and voltage selection are controlled through bits REF EN and REF HI in the setup register. The 2.5V reference requires AVDD = 5V. When using the on-chip voltage reference, the VREFOUT pin should be bypassed with a 0.1 µF capacitor to AGND. VRCAP PIN This pin provides a bypass cap for noise filtering on internal VREF circuitry only. As this is a sensitive pin, place the capacitor as close as possible and avoid any resistive load- ing. The recommended capacitor is a 0.001 µF ceramic cap. If an external VREF is used, this pin can be left unconnected. CLOCK GENERATOR The clock source for the ADS1217 can be provided from a crystal, oscillator, or external clock. When the clock source is a crystal, external capacitors must be provided to ensure start- up and a stable clock frequency; see Figure 2 and Table I. FIGURE 3. Filter Step Responses. SETTLING TIME FILTER (Conversion Cycles) Sinc3 3 Sinc2 2 Fast 1 CONVERSION CYCLE 12 3 4+ Fast Sinc2 Sinc3 Sinc3 AUTO MODE FILTER SELECTION FILTER SETTLING TIME Adjustable Digital Filter Data Out Modulator Output Fast Settling Sinc2 Sinc3 complete both an offset and gain calibration. Self-gain cali- bration is optimized for PGA gains less than 8. When using higher gains, system gain calibration is recommended. For system calibration, the appropriate signal must be applied to the inputs. The system offset command requires a “zero” differential input signal. It then computes an offset that will nullify offset in the system. The system gain command requires a positive “full-scale” differential input signal. It then computes a value to nullify gain errors in the system. Each of these calibrations will take seven tDATA periods to complete. Calibration must be performed after power on, a change in decimation ratio, or a change of the PGA. For operation with a reference voltage greater than (AVDD – 1.5V), the buffer must also be turned off during calibration. At the completion of calibration, the DRDY signal goes LOW, which indicates the calibration is finished and valid data is available. See Application Report Calibration Routine and Register Value Generation for the ADS121x Series (SBAA099) for more information. DIGITAL FILTER The Digital Filter can use either the fast settling, sinc2, or sinc3 filter, as shown in Figure 3. In addition, the Auto mode changes the sinc filter after the input channel or PGA is changed. When switching to a new channel, it will use the fast settling filter; It will then use the sinc2 followed by the sinc3 filter. This combines the low-noise advantage of the sinc3 filter with the quick response of the fast settling time filter. See Figure 4 for the frequency response of each filter. When using the fast setting filter, select a decimation value set by the DEC0 and M/DEC1 registers that is evenly divisible by four for the best gain accuracy. For example, choose 260 rather than 261. FIGURE 2. Crystal Connection. CLOCK PART SOURCE FREQUENCY C1 C2 NUMBER Crystal 2.4576 0-20pF 0-20pF ECS, ECSD 2.45 - 32 Crystal 4.9152 0-20pF 0-20pF ECS, ECSL 4.91 Crystal 4.9152 0-20pF 0-20pF ECS, ECSD 4.91 Crystal 4.9152 0-20pF 0-20pF CTS, MP 042 4M9182 TABLE I. Typical Clock Sources. C 1 Crystal X IN X OUT C 2 CALIBRATION The offset and gain errors in the ADS1217, or the complete system, can be reduced with calibration. Internal calibration of the ADS1217 is called self calibration. This is handled with three commands. One command does both offset and gain calibration. There is also a gain calibration command and an offset calibration command. Each calibration process takes seven tDATA periods to complete. It takes 14 tDATA periods to |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |