22 / 28 page ![]() AD7908/AD7918/AD7928 Data Sheet Rev. E | Page 22 of 28 the operation of the AD7908/AD7918/AD7928 in this mode. In shutdown mode, all internal circuitry on the AD7908/AD7918/ AD7928 is powered down. The part retains information in the control register during shutdown. The AD7908/AD7918/ AD7928 remains in shutdown until the next CS falling edge it receives. On this CS falling edge, the track-and-hold that was in hold while the part was in shutdown returns to track. Wakeup time from auto shutdown is 1 μs, and the user should ensure that 1 μs has elapsed before attempting a valid conversion. When running the AD7908/AD7918/AD7928 with a 20 MHz clock, one dummy cycle should be sufficient to ensure the part is fully powered up. During this dummy cycle the contents of the control register should remain unchanged; therefore the WRITE bit should be 0 on the DIN line. This dummy cycle effectively halves the throughput rate of the part, with every other conversion result being valid. In this mode, the power consumption of the part is greatly reduced with the part entering shutdown at the end of each conversion. When the control register is programmed to move into auto shutdown, it does so at the end of the conversion. The user can move the ADC in and out of the low power state by controlling the CS signal. Powering Up the AD7908/AD7918/AD7928 When supplies are first applied to the AD7908/AD7918/ AD7928, the ADC can power up in any of the operating modes of the part. To ensure the part is placed into the required operating mode, the user should perform a dummy cycle operation as outlined in Figure 24. CS SCLK DOUT DIN 1 16 14 1 PART IS IN FULL SHUTDOWN PART BEGINS TO POWER UP ON CS RISING EDGE AS PM1 = PM0 = 1 THE PART IS FULLY POWERED UP ONCE tPOWER UP HAS ELAPSED CONTROL REGISTER IS LOADED ON THE FIRST 12 CLOCKS. PM1 = 1, PM0 = 1 TO KEEP THE PART IN NORMAL MODE, LOAD PM1 = PM0 = 1 IN CONTROL REGISTER CHANNEL IDENTIFIER BITS + CONVERSION RESULT DATA IN TO CONTROL REGISTER DATA IN TO CONTROL/SHADOW REGISTER 16 14 t12 Figure 22. Full Shutdown Mode Operation 1 CS SCLK DOUT DIN 16 1 6 1 1 16 DUMMY CONVERSION CHANNEL IDENTIFIER BITS + CONVERSION RESULT CHANNEL IDENTIFIER BITS + CONVERSION RESULT INVALID DATA DATA IN TO CONTROL/SHADOW REGISTER DATA IN TO CONTROL/SHADOW REGISTER TO KEEP PART IN THIS MODE, LOAD PM1 = 0, PM0 = 1 IN CONTROL REGISTER OR SET WRITE BIT = 0 PART IS FULLY POWERED UP 12 12 12 PART ENTERS SHUTDOWN ON CS RISING EDGE AS PM1 = 0, PM0 = 1 PART BEGINS TO POWER UP ON CS FALLING EDGE PART ENTERS SHUTDOWN ON CS RISING EDGE AS PM1 = 0, PM0 = 1 CONTROL REGISTER IS LOADED ON THE FIRST 12 CLOCKS, PM1 = 0, PM0 = 1 CONTROL REGISTER CONTENTS SHOULD NOT CHANGE. WRITE BIT = 0 Figure 23. Auto Shutdown Mode Operation 1 CS SCLK DOUT DIN 16 1 16 1 16 DUMMY CONVERSION INVALID DATA KEEP DIN LINE TIED HIGH FOR FIRST TWO DUMMY CONVERSIONS CONTROL REGISTER IS LOADED ON THE FIRST 12 CLOCK EDGES 12 12 12 DUMMY CONVERSION INVALID DATA INVALID DATA DATA IN TO CONTROL REGISTER CORRECT VALUE IN CONTROL REGISTER, VALID DATA FROM NEXT CONVERSION, USER CAN WRITE TO SHADOW REGISTER IN NEXT CONVERSION Figure 24. Placing AD7928 into the Required Operating Mode After Supplies are Applied |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |