6 / 23 page ![]() Inductive loads on/off control AN1172 6/23 2.1.2 Maximum switching frequency As far as thermal management involving clamping phases is concerned, a maximum load commutation frequency must be defined to avoid excessive device heating. Figure 5. gives the maximum supplementary temperature rise due to recurrent clampings, versus the ACS switching period (see Appendix C). This value is given for a 230 V - 50 Hz mains voltage (110 V mains is less stressing), for the worst case of load (power factor = 0.1, peak load current = iH max) and for the maximum VCL and iH values (800 V and 60 mA respectively). In this case, the energy absorbed by the die equals 25 mJ. The chosen package is the TO92 one (ACS108-5SA device) because it presents the highest Rth value, among ACS packages on offer (DIL20, TO92, SOT223, DIL8). It can be seen that this temperature elevation can be neglected (< 4° C) as long as the control frequency is less than one Hertz. Such a value is suitable for most appliance applications where loads are at most controlled once per second. For that reason, in ACS data-sheets, the maximum allowed current is given for a 1 Hertz maximum frequency 0.1 minimum load power factor. Turn-off dissipated power is then reviewed for a wide range of application needs. This enables us to conclude that no varistor is needed across ACSs to clamp the loads inductive energy at turn-off, even with electromagnets which are the highest inductive loads in Appliances. Figure 5. Supplementary temperature elevation due to repetitive clampings (@ clamping energy = 25 mJ, package: TO92) 2.2 Pumps and Fans ON / OFF control 2.2.1 Application requirements for (dI/dt)c and (dV/dt)c There is a higher risk that a triac or an ACS will fail to turn-off when both the load current rate of decrease and the reapplied voltage rate across the device are steep (see References, 3.). This risk increases as the junction temperature increases. The maximum current decreasing rate that ACS can switch off, called (dI/dt)c is defined for a maximum reapplied voltage rate, called (dV/dt)c, and for its maximum Tj. Appliances operation field ACS switching period (T) (s) ∆ T (° C) rep 0 0 0.5 1.0 1.5 2.0 10 20 30 40 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |