Back Button AN4299 Datasheet HTML 6Page - STMicroelectronics AN4299 Datasheet HTML 7Page - STMicroelectronics AN4299 Datasheet HTML 8Page - STMicroelectronics AN4299 Datasheet HTML 9Page - STMicroelectronics AN4299 Datasheet HTML 10Page - STMicroelectronics AN4299 Datasheet HTML 11Page - STMicroelectronics AN4299 Datasheet HTML 12Page - STMicroelectronics AN4299 Datasheet HTML 13Page - STMicroelectronics AN4299 Datasheet HTML 14Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 10 / 20 page
background image
Test set up proposal to detect worst case
AN4299
10/20
DocID024663 Rev 2
3.2
Generator settings
1.
Select “sine wave” and “sweep” mode.
2.
Sweep menu: time = 300 sec, return time = 0, linear, interval = 1 ms
3.
Set Vpp value on the generator to obtain the corresponding voltage injected on the
EUT in case of standard test.
Example: to test in the same condition as the standard at 3 Vrms, you must adjust the
generator voltage to inject 15 Vpp measured on the board with oscilloscope.
Note:
On AFG3102 TEKTRONIX generator, the modulation is not available in sweep mode.
4.
Set the start and end frequencies such that the sweep range does not exceed 60 kHz
for a 300 seconds duration. This recommendation allows to detect worst case level
with sufficient accuracy (typically less than 5 % error).
Note:
An external amplifier might be needed in case the generator would not able to reach the
appropriate injection level.
3.3
Data logging and data processing
Data logging
The STMStudio(a) tool log function can be used to collect data from variable.
Example: “MyChannels_Data[x].Delta” and “MyTKeys[(x)].p_Data->StateId”
Data processing
A graphical tool is recommended for analysis of the results. For example with Microsoft®
Excel® 2D you can obtain the chart shown in Figure 5.
In this example frequency sweep starts at 500 kHz and ends at 550 kHz. Noise level is set
on the generator to 4.6 Vpp (no modulation). Detect out threshold is set to 50, the sensor is
touched and the detection is valid if measured delta is upper 50 else the touch detection is
lost (error is reported). It means that 4.6 Vpp is the limit to avoid detection loss (4.5 Vpp
pass)
As a comparison, IEC61000-4-6 standard recommendation to use 1 % frequency steps
would have lead to explore only ten frequencies in this range, so the chances to detect
worst case would have been very low!
a.
STMStudio: order code STM6STUDIO



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com