9 / 12 page ![]() A165E 9 Safety Precautions Be sure to read the precautions for all A165E models in the website at: http://www.ia.omron.com/. Indication and Meaning for Safe Use !CAUTION If the Operation Unit is separated from the Switch Unit, the equipment will not stop, creating a hazardous condition. Always confirm that safety functions are operating before starting operation. Mounting • Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. Electrical shock or fire may result if the power is not turned OFF. • The tightening torque is 0.29 to 0.49 N·m. Wiring • Be sure to use electrical wires that are a size appropriate for the applied voltage and carry current. Perform soldering according to the conditions given below. If the soldering is not properly performed, abnormal heating may result, possibly resulting in fire. 1. Hand soldering: 30 W, within 5 s 2. Dip soldering: 240 °C, within 3 s Wait for one minute after soldering before exerting any external force on the solder. • Use non-corrosive resin fluid as the flux. • Make sure that the electric cord is wired so that it does not touch the Unit. If the electric cord will touch the Unit, then electric wires with a heat resistance of 100 °C min. must be used. • After wiring the Switch, maintain an appropriate clearance and creepage distance. Operating Environment • The IP65 model is designed with a degree of protection so that it will not sustain damage if it is subjected to water from any direction to the front of the panel. • The Switch is intended for indoor use only. Using the Switch outdoor may cause it to fail. Using the Microload • Insert a contact protection circuit, if necessary, to prevent the reduction of life expectancy due to extreme wear on the contacts caused by loads where inrush current occurs when the contact is opened and closed. • The A165E-@U (one-piece construction) allows both a standard load (125 V at 1 A, 250 V at 0.5 A) and a microload. If a standard load is applied, however, the microload area cannot be used. If the microload area is used with a standard load, the contact surface will become rough, and the opening and closing of the contact for a microload may become unreliable. • The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% ( λ 60) (conforming to JIS C5003). • The equation, λ 60 = 0.5 x 10−6/time indicates that the estimated malfunction rate is less than 1/2,000,000 with a reliability level of 60%. LEDs The LED current-limiting resistor is built-in, so external resistance is not required. Operating Torque • Do not exceed an operating torque of 0.49 N·m in the direction of rotation. • Do not pull the operating button or apply excessive force to any side of the button. Otherwise it may be damaged. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use CAUTION Rated voltage Internal limiting resistor 24 VAC/VDC 2.4 k Ω 0.15 mA 1 mA Area of use Current (mA) Invalid area |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |