XR18910 Datasheet(PDF) 14 Page - Exar Corporation |
|
|
|||||||||||||||||||||||||||||
XR18910 Datasheet(HTML) 14 Page - Exar Corporation |
|
14 / 19 page ![]() 14/19 REV1A Application Information (Continued) Inputs and Input Selection The XR18910 includes 8 differential inputs and a 8:1 differential MUX that is controlled by an I2C compatible 2 wire serial interface. The XR18910 is designed to accept 8 differential inputs. ■ ■ If fewer than 4 differential inputs are required, tie the unused inputs to GND. ■ ■ If single ended inputs are required, tie the unused inputs to 1.5V. The input common mode range of the XR18910 is typically 0.6V to 2.4V when running from a 3.3V supply. The XR18910 offers a very wide gain range. In most cases, the output voltage swing will be the limiting factor. When the XR18910 is powered-up, the default input selected is Channel 1. Inputs are selected via I2C using one of 8 register addresses 0x10, 0x12, 0x14, 0x15, 0x18, 0x1A, 0x1C, or 0x1E. Refer to the Register List in Table 1. Example: The example below illustrates how to select Channel 4. Step 1 0 Master sends start condition S Step 2 7 6 5 4 3 2 1 0 Master sends XR18910 address with write bit 0 1 1 0 1 1 1 0 6 7 W 7-bit XR18910 Address = 0x67 Step 3 9 XR18910 sends acknowledge A Step 4 7 6 5 4 3 2 1 0 Master sends address of register to access 0 0 0 1 0 1 0 1 Select_Input 4 register address = 0x15 Step 5 9 XR18910 sends acknowledge A Step 6 0 Master sends stop condition P NOTES: White Block = host to XR18910, Orange Block = XR18910 to host, Grey Block = Notes. Gain Selection The XR18910 offers 8 selectable fixed gains ranging from 2V/V to 760V/V. When the XR18910 is powered-up, the default gain is 2V/V. The gain is selected via I2C using the register address 0x06 followed by another byte of data to select the gain. Refer to the Register List in Table 1 and the Gain Register list in Table 3. Example: The example below illustrates how to select a gain of 150V/V. To start communication with the XR18910, repeat steps 1-3 as shown in the Inputs and Input Selection section on page 14. Step 4 7 6 5 4 3 2 1 0 Master sends address of register to access 0 0 0 0 0 1 1 0 Gain Select register address = 0x06 Step 5 9 XR18910 sends acknowledge A Since the Gain Select register was accessed, the XR18910 is expecting another byte of data from the master to complete the command. Refer to the “Byte of Parameter” column in the Register List (Table 1). D0 thru D2 are used to select the gain. Refer to the Gain Register list in Table 3, 150V/V is D2 = 1, D1 = 0, and D0 = 0. This translates to a hex code of 0x04, since a full byte of data (8-bits) will be sent. Step 6 7 6 5 4 3 2 1 0 Master sends gain register data to select G=150 0 0 0 0 0 1 0 0 Gain of 150V/V = 0x04 Step 7 9 XR18910 sends acknowledge A Step 8 0 Master sends stop condition P NOTES: White Block = host to XR18910, Orange Block = XR18910 to host, Grey Block = Notes. XR 18910 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |