AD6315 Datasheet(PDF) 8 Page - Anachip Corp

Part # AD6315
Description  1/4- to 1/12 Duty VFD Controller/Driver
PDF  16 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  ANACHIP [Anachip Corp]
Direct Link  
Logo ANACHIP - Anachip Corp

AD6315 Datasheet(HTML) 8 Page - Anachip Corp

Back Button AD6315 Datasheet HTML 4Page - Anachip Corp AD6315 Datasheet HTML 5Page - Anachip Corp AD6315 Datasheet HTML 6Page - Anachip Corp AD6315 Datasheet HTML 7Page - Anachip Corp AD6315 Datasheet HTML 8Page - Anachip Corp AD6315 Datasheet HTML 9Page - Anachip Corp AD6315 Datasheet HTML 10Page - Anachip Corp AD6315 Datasheet HTML 11Page - Anachip Corp AD6315 Datasheet HTML 12Page - Anachip Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 16 page
background image
AD6315
1/4- to 1/12 Duty VFD Controller/Driver
Anachip Corp.
www.anachip.com.tw
Rev. A5 Dec 29, 2003
8/16
(Ⅰ) Display mode setting commands
These commands initialize the AD6315 and select the number of segments and the number of grids
(1/4- to 1/12- duty, 16 segments to 24 segments).
When these commands are executed, the display is forcibly turned off, and key scanning is also stopped.
To resume display, the display command “ON” must be executed. If the same mode is selected, however,
nothing happens.
b2
b1
b0
LSB
MSB
Don't care
Display mode settings
0000: 4digits 24segments
0001: 5digits 23segments
0010: 6digits 22segments
0011: 7digits 21segments
0100: 8digits 20segments
0101: 9digits 19segments
0110: 10digits 18segments
0111: 11digits 17segments
1xxx : 12digits 16segments
0
0
Note: On power application, the 12-digit, 16-segment mode is selected.
(Ⅱ) Data setting commands
These commands set data write and data read modes.
b2
b1
b0
LSB
MSB
Don't care
Daat write and read mode settings
00: Write data to display memory
01: Write data to LED port
10: Read key data
11: Don't card
0
1
b3
Address increment mode settings (Display memory)
0: Increments address after data has been written
1: Fixes address.
Test mode settings
0: Normal operation
1: Test mode
Note: For power application, the normal operation and address increment modes are set.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com