  MAXREFDES113 Datasheet HTML 1Page - Maxim Integrated Products MAXREFDES113 Datasheet HTML 2Page - Maxim Integrated Products MAXREFDES113 Datasheet HTML 3Page - Maxim Integrated Products MAXREFDES113 Datasheet HTML 4Page - Maxim Integrated Products MAXREFDES113 Datasheet HTML 5Page - Maxim Integrated Products MAXREFDES113 Datasheet HTML 6Page - Maxim Integrated Products MAXREFDES113 Datasheet HTML 7Page - Maxim Integrated Products  
Zoom Inzoom in Zoom Outzoom out
 4 / 7 page
background image
VSTART = (R5 + R6 + R7)/(R6 + R7) × 1.21 (V)
VOVI = (R5 + R6 + R7)/R7 × 1.21 (V)
If R5 = 280kΩ, R6 = 13kΩ, and R7 = 10kΩ, then:
VSTART = 15.94V, VOVI = 36.66V.
Quick Start
Required equipment
•
MAXREFDES113# board
•
One 24V DC power supply
•
One electronic load
•
1 voltmeter
•
1 ammeter
Procedure
The MAXREFDES113# board is fully assembled and tested. Use the following steps to verify board
operation.
1. Turn off the power supply.
2. Connect the positive terminal of the power supply to the VIN pin of the MAXREFDES113# board.
3. Connect the negative terminal of the power supply to the PGND pin of the MAXREFDES113# board.
4. Connect the VOUT connector of the MAXREFDES113# board to the positive terminal of the electronic
load.
5. Connect the negative terminal of the electronic load to the positive terminal of the ammeter.
6. Connect the negative terminal of the ammeter to the GNDO connector of the MAXREFDES113# board.
7. Connect the voltmeter across the VOUT and the GNDO connectors of the MAXREFDES113# board.
8. Turn on the power supply.
9. Set the electronic load to a constant current between 0mA to 1.6A.
10. Verify the second voltmeter reading is 12V ±0.6V.
Lab Measurements
The MAXREFDES113# design was verified and tested under full input range and different output load
conditions.
The power efficiency vs. load current is illustrated in Figure 2.



Html Pages

1 2 3 4 5 6 7


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com