| Electronic Components Datasheet Search |
|
ML50.100 Datasheet(PDF) 10 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
ML50.100 Datasheet(HTML) 10 Page - PULS GmbH |
|
10 / 20 page ![]() ML50.100, ML50.109 MiniLine 24V, 2.1A, SINGLE PHASE INPUT Mar. 2007 / Rev. 1.0 DS-ML50.100-EN All parameters are specified at 24V, 2.1A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 10/20 16. EMC The CE mark indicates conformance with EMC guideline 89/336/EEC, 93/68/EEC and the low-voltage directive (LVD) 73/23/EWG. A detailed EMC Report is available on request. EMC Immunity EN 61000-6-2, EN 61000-6-1 Generic standards Electrostatic discharge EN 61000-4-2 Contact discharge Air discharge 8kV 8kV Criterion A Criterion A Electromagnetic RF field EN 61000-4-3 80MHz-1GHz 10V/m Criterion A Fast transients (Burst) EN 61000-4-4 Input lines Output lines 4kV 2kV Criterion A Criterion A Surge voltage on input EN 61000-4-5 L N N / L PE 2kV 4kV Criterion A Criterion A Surge voltage on output EN 61000-4-5 + - + / - PE 500V 500V Criterion A Criterion A Conducted disturbance EN 61000-4-6 0,15-80MHz 10V Criterion A Mains voltage dips EN 61000-4-11 0% of 100Vac 40% of 100Vac 70% of 100Vac 0% of 200Vac 40% of 200Vac 70% of 200Vac 0Vac, 20ms 40Vac, 200ms 70Vac, 500ms 0Vac, 20ms 80Vac, 200ms 140Vac, 500ms Criterion A Criterion C Criterion A Criterion A Criterion A Criterion A Voltage interruptions EN 61000-4-11 0Vac, 5000ms Criterion C Input voltage swells PULS internal standard 300Vac, 500ms Criterion A Powerful transients VDE 0160 over entire load range 750V, 1.3ms Criterion A Criterions: A: Power supply shows normal operation behavior within the defined limits. C: Temporary loss of function is possible. Power supply might shut-down and restarts by itself. No damages or hazards to the power supply will occur. EMC Emission EN 61000-6-3, EN 61000-6-4 Generic standards Conducted emission EN 55011, EN 55022, FCC Part 15, CISPR 11, CISPR 22 Class B, input lines EN 55022 Class B, output lines Radiated emission EN 55011, EN 55022 Class B Harmonic input current EN 61000-3-2 Fulfilled Voltage fluctuations, flicker EN 61000-3-3 Fulfilled This device complies with FCC Part 15 rules. Operation is subjected to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Switching frequency variable, typ. 100kHz, (60-275kHz) Input voltage and output load dependent |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |