3 / 12 page ![]() AND8019/D http://onsemi.com 3 Regulation To measure line regulation, hold the load constant and vary the input over the desired range taking measurements at convenient intervals. The change in output voltage for a fixed load, across the range of input voltages is the line regulation. Load regulation is measured in a similar manner. The line is held constant and the output voltage is measured as the load is varied from minimum to maximum. Ripple The scope should be connected as described in the Measurement Techniques section, and should be ac coupled. Peak–to–peak ripple is the measurement from the lowest point to the highest point on the trace. If a peak–to–mean measurement is desired, set the scope input to ground, move the trace on top of the center graticule line of the scope, and then set the scope coupling back to ac. The voltage from the lowest point on the trace and the highest point on the trace, to the center graticule line are the peak–to–mean measurements. Efficiency Efficiency is defined as: h = Pout/Pin = (Vo Io) / Pin The output power is the output voltage multiplied by the output current. The input power must be read from a quality wattmeter with a wide bandwidth due to the harmonic content of the input current waveform. There is no accurate method of measuring the input power by the use of DVM’s or oscilloscopes. Most wattmeters will also measure power factor, line voltage and line current. Transient Loads Rapid changes in the load of a power converter cause the output voltage to increase or decrease for a short period of time. If the circuit that will be attached to this converter is sensitive to small excursions in voltage, it is highly recommended to test the unit under similar transients. The following exercise will test the unit for a transient from 250 mA to 1.0 A and from 1.0 A to 250 mA. If the actual load transient is different, the loads should be modified to reflect those conditions. Response to load transients can be observed by causing a step load change and synching the oscilloscope to this event. The best way to do this is to replace the switch on the 500 mA load (10 W resistor) with a FET. An ON Semiconductor MTD3302 transistor, driven by a pulse generator with a 0 volt to 10 volt pulse will make a simple electronic switch. Figures 8 and 9 show the transient response to an output load change of 10% to 100% load. Observing the output voltage on an oscilloscope during this event will allow measurement of the level of perturbation as well as the duration. Converter Test Data Parameter Conditions Data Line Regulation 85 V ≤ Vin ≤ 265 V DVo = 6.0 mV Load Regulation 0 A ≤ Io ≤ 1.0 A DVo = 8.0 mV Combined Line/ Load Regulation 85 V ≤ Vin ≤ 265 V 0 A ≤ Io ≤ 1.0 A DVo = 10 mV Output Ripple Io = 1.0 A 100 mVpp Input Power Vin = 115 V, Io = 1.0 A Vin = 220 V, Io = 1.0 A 7.75 watts 7.88 watts Power Factor Vin = 115 V, Io = 1.0 A Vin = 220 V, Io = 1.0 A –0.57 –0.49 Efficiency Vin = 115 V, Io = 1.0 A Vin = 220 V, Io = 1.0 A h = 66% h = 64% Troubleshooting Symptom Solution Unit does not turn on, does not draw current 1. Assure that ac source and meter are properly connected by measuring the voltage at the input connector. 2. Measure the voltage across C2. If it is not approximately equal to the peak input voltage, check for wrong or defective components (R6, R7, D1–D4). 3. Observe voltage at pin 1 of U1. This voltage needs to exceed 8.5 volts for unit to start, and remain greater than 7.5 volts for unit to operate. If not in this range check for shorts, and assure that pin 5 is greater than 50 volts, otherwise replace chip. 4. Measure the voltage at pin 2 of U1. It should measure less than 4.5 volts for PWM to be active. If it is, and the output is not switching, the NCP1000 may be defective. Unit does not turn on, draws excessive current 1. Check for obvious shorts on the board and remove if found. 2. Disconnect all leads and measure resistance across C2. If no short is found, check test setup. If a short is found, isolate it by removing components and testing (D1–D4, C2, U1). • Unit does not regulate 1. Assure that the input voltage and output current are in the specified ranges. 2. Measure voltage across C8. It should be at least twice the output voltage. If not, check D6, L2 and C8. 3. Check the voltage at pin 2. If it is greater than 4.5 volts the opto may be shorted, if 0 the opto may open or C4 may be shorted. 4. Measure voltage at pin 8 of U3 and measure voltage drop across R3. If: • V 8 < 2.5 volts & VR3 = 0 then replace U2. • V 8 < 2.5 volts & VR3 > 0 then replace U3. • V 8 > 2.5 volts & VR3 = 0 then replace U3. • V 8 > 2.5 volts & VR3 > 0 then replace U2. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |