| Electronic Components Datasheet Search |
|
SF2 Datasheet(PDF) 7 Page - Nais(Matsushita Electric Works) |
|
|
|||||||||||||||||||||||||||||
SF2 Datasheet(HTML) 7 Page - Nais(Matsushita Electric Works) |
|
7 / 7 page ![]() 264 SF No.1 No.2 No.3 No.4 No.8 No.7 No.6 No.5 Contact No. No.1 No.2 No.3 No.4 Terminal No. 13–14 5–6 9–10 17–18 No.5 No.6 No.7 No.8 19–20 11–12 7–8 15–16 State of other contacts 12345678 Welded terminal No. 1 >0.5 >0.5 ≠ >0.5 ≠ >0.5 ≠ 2 >0.5 >0.5 >0.5 >0.5 3 >0.5 >0.5 >0.5 >0.5 4 ≠ >0.5 >0.5 ≠ >0.5 ≠ >0.5 5 >0.5 ≠ >0.5 ≠ >0.5 >0.5 ≠ 6 >0.5 >0.5 >0.5 >0.5 7 >0.5 >0.5 >0.5 >0.5 8 ≠ >0.5 ≠ >0.5 ≠ >0.5 >0.5 Note: Contact gaps are shown at the initial state. If the contacts change state owing to loading/breaking it is necessary to check the actual loading. >0.5: contact gap is kept at min. 0.5 mm .020 inch ≠: contact closed Empty cells: either closed or open Contact No. Contact No. The table below shows the state of the other contacts when the current through the welded form “a” contact is 0 V and the rated volt- age is applied through the form “b” contact. Contact Operation Table If the No. 2 contact welds. Each of the four form "a" contacts (Nos. 1, 3, 5, and 7) maintains a gap of greater than 0.5 mm .020 inch. No.1 No.2 No.3 No.4 No.8 No.7 No.6 No.5 Non-energized No.1 No.2 No.3 No.4 No.8 No.7 No.6 No.5 Energized (when no. 2 contact is welded) 3) 4a4b Type If the internal contacts (nos. 2, 3, 6, and 7) weld, the armature becomes non-operational and the contact gaps of each of the four form “a” contacts are maintained at greater than 0.5 mm .020 inch. Reliable isolation is thus ensured. Internal Contacts Weld If the external contacts (nos. 1, 4, 5, and 8) weld, gaps of greater than 0.5 mm .020 inch are maintained between adjacent contacts and the coil returns to an non-energized state. External Contacts Weld If external connections are made in series. Even if one of the contacts welds, because the other contacts operate independently, the contact gaps are maintained at greater than 0.5 mm .020 inch. Energized Contact gap min 0.5 mm .020 inch Weld Non-energized If the No. 1 contact welds. The adjacent No. 2 contact maintains a gap of greater than 0.5 mm .020 inch. The other con- tacts, because the coil is not energized, return to their normal return state; each of form “a” con- tacts (nos. 3, 5, and 7) maintains a contact gap of greater than 0.5 mm .020 inch; each of the form “b” contacts (nos. 4, 6, and 8) return to a closed state. No.1 No.2 No.3 No.4 No.8 No.7 No.6 No.5 Energized No.1 No.2 No.3 No.4 No.8 No.7 No.6 No.5 Non-energized (when no. 1 contact is welded) For Cautions for Use, see Relay Technical Information (Page 48 to 76). 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |