| Electronic Components Datasheet Search |
|
BD2326 Datasheet(PDF) 2 Page - BeRex Corporation |
|
|
|||||||||||||||||||||||||||||
BD2326 Datasheet(HTML) 2 Page - BeRex Corporation |
|
2 / 4 page ![]() 2 Typical Test Data Insertion Loss vs. Frequency Isolation vs. Frequency IRL vs. Frequency ORL vs. Frequency Triple Band 2-Way SMT Power Divider BD2326 1900~2500MHz PCS, WCDMA & TD-SCDMA, WiBro Parameters Unit WCDMA & TD-SCDMA WiBro Frequency Range MHz 1900 2075 2250 2200 2350 2500 Insertion Loss dB 0.58 0.59 0.64 0.62 0.69 0.77 Isolation dB 23.33 27.55 23.28 24.47 19.58 15.03 IRL(S11) dB 17.93 17.05 14.94 15.89 13.83 12.10 ORL(S22,S33) dB 21.92 23.04 22.90 22.81 22.00 20.09 Phase Diff. deg 0.69 0.76 0.60 0.84 0.56 0.62 Amplitude Balance dB 0.03 0.04 0.06 0.05 0.06 0.09 BeRex ●website: www.berex.com ●email: sales@berex.com Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex. All other trademarks are the property of their respective owners. © 2010 BeRex Rev. D |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |