2 / 10 page ![]() cui.com date 12/08/2017 │ page 2 of 10 CUI Inc │ SERIES: PBO-1 │ DESCRIPTION: AC-DC POWER SUPPLY INPUT parameter conditions/description min typ max units voltage 85 70 305 430 Vac Vdc frequency 47 63 Hz current at 115 Vac at 277 Vac 0.12 0.06 A A inrush current at 115 Vac at 277 Vac 9 15 A A no load power consumption 24 Vdc output models all other models 0.3 0.25 W W OUTPUT parameter conditions/description min typ max units capacitive load 5 Vdc output models all other models 220 100 µF µF initial set point accuracy 5 Vdc output models all other models ±8 ±5 % % line regulation at full load ±1.5 % load regulation from 5~100% load ±2.5 % hold-up time at 230 Vac 150 180 ms switching frequency 100 kHz temperature coefficient ±0.15 %/°C PROTECTIONS parameter conditions/description min typ max units over current protection auto recovery 110 500 % short circuit protection continuous, auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute 3,000 Vac safety approvals UL 60950-1, EN 60950-1, IEC 60950-1 safety class Class II conducted emissions CISPR32/EN55032, Class A (external circuit required, see Figure 1) CISPR32/EN55032, Class B (external circuit required, see Figure 2) radiated emissions CISPR32/EN55032, Class A (external circuit required, see Figure 1) CISPR32/EN55032, Class B (external circuit required, see Figure 2) ESD IEC/EN61000-4-2, contact ±4 kV, Class B radiated immunity IEC/EN61000-4-3, 10V/m, Class A (external circuit required, see Figure 2) EFT/burst IEC/EN61000-4-4, ±2 kV, Class B (external circuit required, see Figure 1) IEC/EN61000-4-4, ±4 kV, Class B (external circuit required, see Figure 2) surge IEC/EN61000-4-5, line to line ±1 kV, Class B (external circuit required, see Figure 1) IEC/EN61000-4-5, line to line ±1 kV/line to ground ±2 kV, Class B (external circuit required, see Figure 2) conducted immunity IEC/EN61000-4-6, 10 Vr.m.s, Class A (external circuit required, see Figure 2) voltage dips & interruptions IEC/EN61000-4-11 Class B, 0%-70% (external circuit required, see Figure 2) MTBF as per MIL-HDBK-217F at 25°C 200,000 hours RoHS 2011/65/EU Notes: 1. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives. For more information, please visit the product page | If your application requires forced air, view our Dc Fans |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |