| Electronic Components Datasheet Search |
|
LTM4675 Datasheet(PDF) 76 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTM4675 Datasheet(HTML) 76 Page - Linear Technology |
|
76 / 128 page ![]() LTC3884/LTC3884-1 76 3884fe For more information www.linear.com/LTC3884 PMBus COMMAND DETAILS A shortCycle event occurs whenever the PWM channel is commanded back ON, or reactivated, after the part has been commanded OFF and is processing either the TOFF_DELAY or the TOFF_FALL states. The PWM channel can be turned ON and OFF through either the RUN pin and or the PMBus OPERATION command. If the PWM channel is reactivated during the TOFF_DELAY, the part will perform the following: 1. Immediately tri-state the PWM channel output; 2. Start the retry delay timer as specified by the tOFF(MIN). 3. After the tOFF(MIN) value has expired, the PWM channel will proceed to the TON_DELAY state and the STATUS_ MFR_SPECIFIC bit #1 will assert. If the PWM channel is reactivated during the TOFF_FALL, the part will perform the following: 1. Stop ramping down the PWM channel output; 2. Immediately tri-state the PWM channel output; 3. Start the retry delay timer as specified by the tOFF(MIN). 4. After the tOFF(MIN) value has expired, the PWM channel will proceed to the TON_DELAY state and the STATUS_ MFR_SPEFIFIC bit #1 will assert. If the SHORT Cycle event occurs and the ShortCycle MFR_CHAN_CONFIG bit is not set, the PWM channel state machine will complete its TOFF_DELAY and TOFF_FALL operations as previously commanded by the user. MFR_CONFIG_ALL General purpose configuration command common to multiple ADI products. BIT MEANING 7 Enable Fault Logging. 6 Ignore Resistor Configuration Pins. 5 Mask PMBus, PartII, Section 10.9.1 Violations. 4 Disable SYNC output. 3 Enable 255ms PMBus timeout. 2 PMBus command writes require a valid Packet Error Checking, PEC, byte to be accepted.* 1 Enable the use of PMBus clock stretching. 0 Execute CLEAR_FAULTS on rising edge of either RUN pin. *PMBus command writes that have a valid PEC byte are always processed. PMBus command writes that have an invalid PEC byte are not processed and set a CML status fault. This command has one data byte. ON/OFF/MARGIN COMMAND NAME CMD CODE DESCRIPTION TYPE PAGED DATA FORMAT UNITS NVM DEFAULT VALUE ON_OFF_CONFIG 0x02 RUN pin and PMBus bus on/off command configuration. R/W Byte Y Reg Y 0x1E OPERATION 0x01 Operating mode control. On/off, margin high and margin low. R/W Byte Y Reg Y 0x80 MFR_RESET 0xFD Commanded reset without requiring a power-down. Send Byte N NA |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |