| Electronic Components Datasheet Search |
|
AD9737ABBCZ Datasheet(PDF) 46 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9737ABBCZ Datasheet(HTML) 46 Page - Analog Devices |
|
46 / 64 page ![]() AD9737A/AD9739A Data Sheet Rev. D | Page 46 of 64 CLK INPUT COMMON MODE Table 23. CLK Input Common Mode Register (CROSS_CNT1 and CROSS_CNT2) Address (Hex) Bit Name Bits R/W Default Setting Description 0x22 DIR_P 4 R/W 0x0 DIR_P and DIR_N. 0 = VCM at the DACCLK_P input decreases with the offset value. 1 = VCM at the DACCLK_P input increases with the offset value. CLKx_OFFSET sets the magnitude of the offset for the DACCLK_P and DACCLK_N inputs. For optimum performance, set to 1111. CLKP_OFFSET[3:0] [3:0] R/W 0x0000 0x23 DIR_N 4 R/W 0x0 CLKN_OFFSET[3:0] [3:0] R/W 0x0000 MU CONTROLLER CONFIGURATION AND STATUS Table 24. Mu Controller Configuration and Status Register (PHS_DET, MU_DUTY, MU_CNT[1:4], and MU_STAT1) Address (Hex) Bit Name Bits R/W Default Setting Description 0x24 CMP_BST 5 R/W 0x0 Phase detector enable and boost bias bits. PHS_DET AUTO_EN 4 R/W 0x0 Note that both bits should always be set to 1 to enable these functions. 0x25 MU_ DUTYAUTO_EN 7 R/W 0x0 Mu controller duty cycle enable. Note that this bit should always be set to 1 to enable. 0x26 Slope 6 R/W 0x1 Mu controller phase slope lock. 0 = negative slope, 1 = positive slope. Note that a setting of 0 is recommended for best ac performance. Mode[1:0] [5:4] R/W 0x00 Sets the Mu controller mode of operation. 00 = search and track (recommended). 01 = search only. 10 = track. Read 3 R/W 0x0 Set to 1 to read the current value of the Mu delay line in. Gain[1:0] [2:1] R/W 0x01 Sets the Mu controller tracking gain. Recommended to leave at the default 01 setting. Enable 0 R/W 0x0 0 = disable the Mu controller. 1 = enable the Mu controller. 0x27 MUDEL[0] 7 R/W 0x0 The LSB of the 9-bit MUDEL setting. SRCH_MODE[1:0] [6:5] R/W 0x0 Sets the direction in which the Mu controller searches (from its initial MUDEL setting) for the optimum Mu delay line setting that corresponds to the desired phase/slope setting (that is, SET_PHS and slope ). 00 = down. 01 = up. 10 = down/up (recommended). SET_PHS[4:0] [4:0] R/W 0x0 Sets the target phase that the Mu controller locks to with a maximum setting of 16. A setting of 4 (that is, 00100) is recommended for optimum ac performance. 0x28 MUDEL[8:1] [7:0] W 0x00 With enable (Bit 0, Register 0x26) set to 0, this 9-bit value represents the value that the Mu delay is set to. Note that the maximum value is 432. With enable set to 1, this value represents the Mu delay value at which the controller begins its search. Setting this value to the delay line midpoint of 216 is recommended. R 0x00 When read (Bit 3, Register 0x26) is set to 1, the value read back is equal to the value written into the register when enable = 0 or the value that the Mu controller locks to when enable = 1. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |