10 / 11 page ![]() QUINT-PS-3x400-500AC/24DC/20 100034_04_en PHOENIX CONTACT 10 Signal Loop Figure 12 Signal loop The two signal outputs described above can be easily combined. Example: Monitoring two devices Use the active alarm output of device 1 and loop in the floating alarm output of device 2. In the event of an error, a group error message is output. Any number of devices can be looped. This signal combination saves wiring costs and logic inputs. Status Indicator: DC OK LED The green DC OK LED enables local function evaluation in the control cabinet. Function Output Characteristic Curve Figure 13 Output characteristic curve At ambient operating temperatures Tamb <+40°C, the device can continuously supply an IBOOST current at nominal voltage. In the event of heavier loads the working point demonstrates the U/I characteristic curve shown in the figure. The output current is limited to IBOOST. The secondary voltage is reduced until the short circuit on the secondary side is removed. The U/I characteristic curve ensures that both heavy capacitive loads and loads with DC/DC converters can be supplied by QUINT POWER in the input circuit. Connected fuses are tripped. The selectivity in your system configuration is ensured at all times. – UN = +24 V – IN = 20 A – IBOOST = 27 A – PN = 480 W – PBOOST = 624 W DC OK + Output 13 Output 14 + - - ++ 13 13 14 14 ++ -- -- 12 DC OK LED ON Flashing OFF Active DC OK switching output U = +24 V (with reference to "-") U = 0 V (with reference to "-") U = 0 V (with reference to "-") Floating DC OK output Closed Open Open Cause Output voltage greater than 90% of the set voltage Output voltage less than 90% of the set voltage No voltage at the output Meaning Output voltage and current OK QUINT POWER operating, but: – Error at the load – Current consumption greater than IBOOST – Output short circuit QUINT POWER not operating, because: – No mains voltage present – The primary side fuse has blown – The device is faulty P BOOST I BOOST P N IN < 40°C < 60°C U [V] U OUT N I [A] OUT |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |