| Electronic Components Datasheet Search |
|
KUSB-488B Datasheet(PDF) 7 Page - TEKTRONIX, INC. |
|
|
|||||||||||||||||||||||||||||
KUSB-488B Datasheet(HTML) 7 Page - TEKTRONIX, INC. |
|
7 / 12 page ![]() TEK.COM 7 Series 2400 SourceMeter® SMU Instruments Datasheet Resistance Measurement Accuracy (Local or Remote Sense) 1, 2, 5 Range Default Resolution Default Test Current 2400, 2401, 2410 Default Test Current 2420, 2440 Normal Accuracy (23°C ±5°C) 1 Year, ±(% rdg. + ohms) Enhanced Accuracy (23°C ±5°C)4 1 Year, ±(% rdg. + ohms) 2400, 2401 2410 2420, 2440 2400, 2401 <0.20000 Ω3 – – – Source I ACC + Meas. V ACC Source I ACC + Meas. V ACC Source I ACC + Meas. V ACC Source I ACC + Meas. V ACC 2.00000 Ω3 10 µΩ – 1 A Source I ACC + Meas. V ACC Source I ACC + Meas. V ACC 0.17% + 0.0003 Ω Source I ACC + Meas. V ACC 20.0000 Ω 100 µΩ 100 mA 100 mA 0.10% + 0.003 Ω 0.11% + 0.006 Ω 0.10% + 0.003 Ω 0.07% + 0.001 Ω 200.000 Ω 1 mΩ 10 mA 10 mA 0.08% + 0.03 Ω 0.09% + 0.1 Ω 0.08% + 0.03 Ω 0.05% + 0.01 Ω 2.00000 kΩ 10 mΩ 1 mA 1 mA 0.07% + 0.3 Ω 0.08% + 0.6 Ω 0.07% + 0.3 Ω 0.05% + 0.1 Ω 20.0000 kΩ 100 mΩ 100 µA 100 µA 0.06% + 3 Ω 0.07% + 6 Ω 0.06% + 3 Ω 0.04% + 1 Ω 200.000 kΩ 1 Ω 10 µA 10 µA 0.07% + 30 Ω 0.07% + 60 Ω 0.07% + 30 Ω 0.05% + 10 Ω 2.00000 MΩ6 10 Ω 1 µA 1 µA 0.11% + 300 Ω 0.12% + 600 Ω 0.11% + 300 Ω 0.05% + 100 Ω 20.0000 MΩ7 100 Ω 1 µA 1 µA 0.11% + 1 kΩ 0.12% + 2.4 kΩ 0.11% + 1 kΩ 0.05% + 500 Ω 200.000 MΩ3 1 kΩ 100 nA – 0.66% + 10 kΩ 0.66% + 24 kΩ Source I ACC + Meas. V ACC 0.35% + 5 kΩ >200.000 MΩ3 – – – Source I ACC + Meas. V ACC Source I ACC + Meas. V ACC Source I ACC + Meas. V ACC Source I ACC + Meas. V ACC Temperature Coefficient (0°–18°C and 28°–50°C) ±(0.15 × accuracy specification)/°C. Source I Mode, Manual Ohms Total uncertainty = I source accuracy + V measure accuracy (4-wire remote sense). Source V Mode, Manual Ohms Total uncertainty = V source accuracy + I measure accuracy (4-wire remote sense). 6-wire Ohms Mode Available using active ohms guard and guard sense. Max. Guard Output Current: 50 mA (except 1 A range). Accuracy is load dependent. Refer to White Paper below for calculation formula: “Obtaining More Accurate Resistance Measurements Using the 6-wire Ohms Measurement Technique.” Guard Output Impedance <0.1Ω in ohms mode. NOTES 1. Speed = Normal (1 PLC). For 0.1 PLC, add 0.005% of range to offset specifications, except 200 mV, 1 A, 10 A ranges, add 0.05%. For 0.01 PLC, add 0.05% of range to offset specifications, except 200 mV, 1 A, 10 A ranges, add 0.5%. 2. Accuracies apply to 2- or 4-wire mode when properly zeroed. 3. Manual ohms only – except 2420, 2440 for 2 Ω range and 2400, 2401, or 2410 for 200 MΩ range. 4. Source readback enabled, offset compensation ON. Also available on 2410, 2420, and 2440 with similar accuracy enhancement. 5. In pulse mode, limited to 0.1 PLC measurement. 6. Except 2440; default test current is 5 µA. 7. Except 2440; default test current is 0.5 µA. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |