65 / 107 page ![]() ams Datasheet Page 65 [v1-11] 2018-Nov-14 Document Feedback AS3956 − Detailed Description Direct Command Mode Direct Command Mode is comprised of one command byte followed by argument byte. SPI operation mode bits 11b indicate Direct Command Mode. The following six bits define command code, sent MSB first. Last two bits in argument byte indicate success of the direct command. Value 01h of the argument byte indicates that command was accepted, while value 02h indicates rejected due to internal access priorities. The argument byte does not provide information on timing of the command execution. Figure 63: Sending a Direct Command over SPI 1 1 C5 C4 C3 C2 C1 C0 X X SCLK rising edge Data is transferred from µC SCLK falling edge Data is sampled Two leading ONE indicate COMMAND Mode D7 D6 D5 D4 D3 D2 D1 D0 /SS SCLK MOSI |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|