21 / 29 page ![]() ESD Protection The IC requires no external ESD protection. All Maxim devices incorporate ESD protection structures to protect against electrostatic discharges encountered during han- dling, assembly, and system-level operation. When used with the configuration shown in the Typical Application Circuit, the IC is characterized for protection to the fol- lowing limits: ● ±25kV ISO 10605 Air Gap ● ±8kV ISO 10605 Contact Discharge ● ±15kV IEC 61000-4-2 Air Gap ● ±8kV IEC 61000-4-2 Contact Discharge ● ±15kV 330Ω, 330pF Air Gap ● ±8kV 330Ω, 330pF Contact Discharge Note: All application-level ESD testing is performed on the standard evaluation kit. ESD Test Conditions ESD performance depends on a variety of conditions. Contact Maxim for test setup, test methodology, and test results. Human Body Model Figure 4 shows the Human Body Model and Figure 5 shows the current waveform it generates when dis- charged into a low impedance. This model consists of a 100pF capacitor charged to the ESD voltage of interest, which is then discharged into the device through a 1.5kΩ resistor. IEC 61000-4-2 The IEC 61000-4-2 standard covers ESD testing and performance of finished equipment. The IC helps users design equipment that meet Level 4 of IEC 61000-4-2. The main difference between tests done using the Human Body Model and IEC 61000-4-2 is higher peak current in IEC 61000-4-2. Because series resistance is lower in the IEC 61000-4-2 ESD test model (Figure 4), the ESD withstand voltage measured to this standard is generally lower than that measured using the Human Body Model (Figure 5). Figure 6 shows the current waveform for the ±8kV, IEC 61000-4-2 Level 4, ESD Contact Discharge test. The Air Gap Discharge test involves approaching the device with a charged probe. The Contact Discharge method connects the probe to the device before the probe is energized. Figure 4. IEC 61000-4-2 ESD Test Model Figure 5. Human Body Current Waveform Figure 6. IEC 61000-4-2 ESD Generator Current Waveform RC 1MΩ DEVICE UNDER TEST HIGH- VOLTAGE DC SOURCE STORAGE CAPACITOR CS 100pF CHARGE CURRENT-LIMIT RESISTOR RD 1.5kΩ DISCHARGE RESISTANCE IPEAK (AMPS) 100% 90% 10% tRL tDL t 36.8% 0 0 IR 100% 90% 10% tR = 0.7ns TO 1ns 30ns 60ns t IPEAK (AMPS) MAX20047 Dual 3A USB DCP Charger www.maximintegrated.com Maxim Integrated │ 21 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |