8 / 26 page ![]() ZMOD4410 Datasheet © 2021 Renesas Electronics Corporation 8 December 17, 2021 7. Sensor Module Characteristics 7.1 Gas Sensor Module The ZMOD4410 Gas Sensor Module is designed to detect typical TVOC contaminations based on studies and international standards for indoor air quality. Characteristic module parameters are shown in Table 5. The response time for a gas stimulation is always within a few seconds, depending on the TVOC and its concentration. An active or direct airflow onto the sensor module is not necessary because diffusion of ambient gas does not limit the sensor module’s response time. Important: The ZMOD4410 also can detect safety-relevant gases for indoor air, such as carbon monoxide (CO); however, the sensor module is not designed to detect these interferants reliably and therefore it is not approved for use in any safety-critical or life-protecting applications. It must not be used in such applications, and Renesas disclaims all liability for any such use. Table 5. Gas Sensor Module Specifications during Operation Symbol Parameter Conditions Minimum Typical Maximum Unit [a] Resistance Measurement Range Ethanol in air 0 1000 ppm 0 1000000 ppb [b] IAQ Specified Measurement Range [c] Ethanol in air 160 10000 ppb Humidity Range Non-condensing 0 90 % RH S Sensitivity over Lifetime Resistance in Air / Resistance at 10ppm Ethanol (RAir/RGas) 5 Ω/Ω T-80 Sensor Module Response Time [d] Time to change to 80% of end value 10 s [a] The abbreviation ppm stands for “parts per million,” and ppb is an abbreviation for “parts per billion” (e.g., 1ppm equals 1000ppb). [b] Conversion from ppm to mg/m3 for most common TVOC is by the factor approximately 2 (e.g., 5ppm equals approximately 10mg/m3). [c] Source: Umweltbundesamt, Beurteilung von Innenraumluftkontaminationen mittels Referenz- und Richtwerten, (Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz, 2007). [d] Response times depend on TVOC gas and concentration. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |