Back Button ZMOD4410AI2R Datasheet HTML 6Page - Renesas Technology Corp ZMOD4410AI2R Datasheet HTML 7Page - Renesas Technology Corp ZMOD4410AI2R Datasheet HTML 8Page - Renesas Technology Corp ZMOD4410AI2R Datasheet HTML 9Page - Renesas Technology Corp ZMOD4410AI2R Datasheet HTML 10Page - Renesas Technology Corp ZMOD4410AI2R Datasheet HTML 11Page - Renesas Technology Corp ZMOD4410AI2R Datasheet HTML 12Page - Renesas Technology Corp ZMOD4410AI2R Datasheet HTML 13Page - Renesas Technology Corp ZMOD4410AI2R Datasheet HTML 14Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 10 / 26 page
background image
ZMOD4410 Datasheet
© 2021 Renesas Electronics Corporation
10
December 17, 2021
8.1 IAQ 2nd Generation (Absolute Measurement)
These operation modes are used for absolute measurements of indoor air quality (IAQ) according to UBA with eCO2.
The following sections provide information on TVOC gases, concentrations, and thresholds given by the German Federal Environmental Agency
(UBA) * and the US Environmental Protection Agency (EPA). These standards provide reliable information on indoor air quality and
recommendations for air improvements if necessary.
8.1.1 Air Quality – IAQ Levels according to UBA
The algorithm provided by Renesas for the user’s microprocessor uses the output from the ZMOD4410 to determine the relative level of TVOC
gases present (see ZMOD4410 Programming Manual – Read Me; see also section 12). The algorithm features an automated baseline
correction function, ensuring that the module can learn from its environment and distinguish elevated levels of TVOC under all conditions. The
proprietary metal oxide (MOx) used in the sensor module allows it to respond effectively to changing TVOC levels during long-term operation.
Renesas has adopted the definition of TVOCs and their impact on user health and comfort proposed by the UBA (see Table 7). The ZMOD4410
can detect the presence of elevated TVOC levels as described in the UBA study.*
There are many sources of poor indoor air quality that can elevate TVOC levels in the typical home or office environments, and the types of
TVOC that might be present can vary widely. Additional information on this topic is available in Renesas’ ZMOD4410 White Paper – Overview
of TVOC and Indoor Air Quality.
The ZMOD4410 can respond reliably to all of the types of organic compounds that are typically found in indoor environments. To assess the
response of the gas sensor module to the levels described in the UBA study, the module has been tested using several TO-15/17 multi-
component TVOC standards defined by the EPA. The ZMOD4410 response to the EPA standard with the TVOC levels from UBA is shown in
Figure 3. A third-party report and certification from an independent research lab is available on the Renesas website that confirms the good
conformity for IAQ measurements with respect to the UBA study and EPA standard.
Table 7.
Level of Indoor Air Quality Based on TVOC Levels Described by UBA
Renesas IAQ Rating
Reference Level*
Air Information
TVOC (mg/m3) [a]
Air Quality
≤ 1.99
Level 1
Clean Hygienic Air
(target value)
< 0.3
Very Good
2.00 to 2.99
Level 2
Good Air Quality
(if no threshold value is exceeded)
0.3 to 1.0
Good
3.00 to 3.99
Level 3
Noticeable Comfort Concerns
(not recommended for exposure > 12 months)
1.0 to 3.0
Medium
4.00 to 4.99
Level 4
Significant Comfort Issues
(not recommended for exposure > 1 month)
3.0 to 10.0
Poor
≥ 5.00
Level 5
Unacceptable Conditions
(not recommended)
> 10.0
Bad
[a]
Conversion from mg/m3 to ppm for many common TVOC is by the factor approximately 0.5 (e.g., 10mg/m3 equals approximately 5ppm). Conversion
from ppm to ppb is by the factor 1000 (e.g., 0.1ppm equals 100ppb).
* Umweltbundesamt, Beurteilung von Innenraumluftkontaminationen mittels Referenz- und Richtwerten, (Bundesgesundheitsblatt - Gesundheitsforschung -
Gesundheitsschutz, 2007).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com