| Electronic Components Datasheet Search |
|
RF-13 Datasheet(PDF) 15 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
RF-13 Datasheet(HTML) 15 Page - Panasonic Semiconductor |
|
15 / 24 page ![]() 14 Type Thru-beam Retroreflective Long sensing range With polarizing filters Light-ON Dark-ON Light-ON Dark-ON Light-ON Dark-ON NPN output CX-411A-C05 CX-411B-C05 CX-412A-C05 CX-412B-C05 CX-491A-C05-Y CX-491B-C05-Y Item PNP output CX-411A-P-C05 CX-411B-P-C05 CX-412A-P-C05 CX-412B-P-C05 CX-491A-P-C05-Y CX-491B-P-C05-Y Applicable CE marking directive EMC Directive, RoHS Directive Sensing range 10 m 32.808 ft 15 m 49.213 ft 3 m 9.843 ft (Note 2) Sensing object ø12 mm ø0.472 in or more opaque object (Note 3) ø50 mm ø1.969 in or more transparent, translucent or opaque object (Note 2, 4) Hysteresis Repeatability (perpendicular to sensing axis) 0.5 mm 0.020 in or less Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less Current consumption Emitter: 15 mA or less Receiver: 10 mA or less Emitter: 20 mA or less Receiver: 10 mA or less 13 mA or less Output <NPN output type> NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 2 V or less (at 100 mA sink current) 1 V or less (at 16 mA sink current) <PNP output type> PNP open-collector transistor • Maximum source current: 100 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 2 V or less (at 100 mA source current) 1 V or less (at 16 mA source current) Short-circuit protection Incorporated Response time 1 ms or less Operation indicator Orange LED (lights up when the output is ON)(incorporated on the receiver for thru-beam type) Stability indicator Green LED (lights up under stable light received condition or stable dark condition)(incorporated on the receiver for thru-beam type) Power indicator Green LED (lights up when the power is ON) (incorporated on the emitter) Sensitivity adjuster Automatic interference prevention function Two units of sensors can be mounted close together with interference prevention filters. (Sensing range: 5 m 16.404 ft) Incorporated (Two units of sensors can be mounted close together.) Protection IP67 (IEC) Ambient temperature -25 to +55 °C -13 to +131 °F (No dew condensation or icing allowed), Storage: -30 to +70 °C -22 to +158 °F Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,000 ℓx at the light-receiving face Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each Emitting element (modulated) Red LED Infrared LED Red LED Peak emission wavelength 680 nm 0.027 mil 870 nm 0.034 mil 680 nm 0.027 mil Material Enclosure: PBT (Polybutylene terephthalate), Lens: Acrylic, Indicator cover: Acrylic Cable 0.2 mm2 3-core (thru-beam type emitter: 2-core) cabtyre cable, 0.5 m 1.640 ft long Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver) Weight Net Emitter: 20 g approx., Receiver: 20 g approx. 20 g approx. Gross 50 g approx. 30 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-230 reflector (optional). The sensing range represents the actual sensing range of the sensor. The sensing range: A of the table below may vary depending on the shape of sensing object. Be sure to check the operation with the actual sensing object. Setting range of the reflector: B Sensing object Sensing range: A Sensor Reflector (Optional) CX-491□ A 0 to 3 m 0 to 9.843 ft B 0.1 to 3 m 0.328 to 9.843 ft 3) If slit masks (optional) are fitted, an object of ø0.5 mm ø0.020 in (using round slit mask) can be detected. 4) Make sure to confirm detection with an actual sensor before use. SPECIFICATIONS Basic type |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |