91 / 96 page ![]() ISL68226 10. PMBus Command Detail FN9329 Rev.1.00 Page 91 of 95 Oct.1.20 10.90 SLOW_OC_FILT_COUNT (ECh) Definition: Sets the slow sum output overcurrent fault filter settings. Access: Paged Data Length in Bytes: 2 Data Format: Bit Field Type: R/W Default Value: 606h (Filter = 10.6µs, Delay = 1024µs) Command SLOW_OC_FILT_COUNT (ECh) Format Bit Field Bit Position 15 14 13 12 11 10 987 6543 210 Access R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W Function See Following Table Default Value 0000 01100 0000 110 Bit Number Purpose Setting 15:12 Not Used Not used 11:8 Filter Setting Time constant = 166.7ns * 2^direct value. Range is 167ns to 5.46ms. 7:0 Delay Setting Delay 170.7µs * direct value before a fault is generated. Range is 0µs to 43.5ms. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|