| Electronic Components Datasheet Search |
|
VCNL4020C Datasheet(PDF) 12 Page - Vishay Siliconix |
|
|
|||||||||||||||||||||||||||||
VCNL4020C Datasheet(HTML) 12 Page - Vishay Siliconix |
|
12 / 16 page ![]() VCNL4020C www.vishay.com Vishay Semiconductors Rev. 1.1, 20-Mar-18 12 Document Number: 84350 For technical questions, contact: sensorstechsupport@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Example: read register “Ambient Light Result Register” #5 and #6: Addressing:command: 26h, 85h (VCNL4020C_I2C_Bus_Write_Adr., Ambient Light Result Register #5 [85]) Read register #5:command: 27h, data (VCNL4020C_I2C_Bus_Read_Adr., {High Byte Data of Ambient Light Result register #5 [85])} Read register #6:command: 27h, data (VCNL4020C_I2C_Bus_Read_Adr., {Low Byte Data of Ambient Light Result register #6 [86])} 3.3 Continuous Conversion Mode in Ambient Light Measurement In the following is a detail description of the function “continuous conversion” (bit 7 of register #4) Standard mode (bit 7 of reg #4 = 0): In standard mode the ambient light measurement is done during a fixed time frame of 100 ms. The single measurement itself takes actually only appr. 300 μs. The following figures show examples of this measurement timing in standard mode using averaging function 2 and 8 as examples for illustration (possible values up to 128). Fig. 15 - Ambient Light Measurement with Averaging = 2; Final Measurement Result = Average of these 2 Measurements Fig. 16 - Ambient Light Measurement with Averaging = 8; Final Measurement Result = Average of these 8 Measurements Note • ≥ Independent of setting of averaging the result is available only after 100 ms. Continuous conversion mode (bit 7 of register #4 = 1): In continuous conversion mode the single measurements are done directly subsequent after each other. See following examples in figure 17 and 18 Fig. 17 - Ambient Light Measurement with Averaging = 2; using Continuous Conversion Mode Fig. 18 - Ambient Light Measurement with Averaging = 8; using Continuous Conversion Mode 50 ms 100 ms Start 22315 12.5 ms Start 100 ms 22316 460 μs Start 1.5 ms 22317 460 μs Start 4.2 ms 22318 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |