| Electronic Components Datasheet Search |
|
LAD-360D Datasheet(PDF) 2 Page - Mean Well Enterprises Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
LAD-360D Datasheet(HTML) 2 Page - Mean Well Enterprises Co., Ltd. |
|
2 / 12 page ![]() SPECIFICATION FOR FUNCTION MODEL (Blank Version) TTL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT SAFETY STANDARDS WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSION OTHERS NOTE PACKING OVERLOAD OVER VOLTAGE BATTERY CUTOFF AC CURRENT (Typ.) UL62368-1, approved; BS EN/EN62368-1 AS/NZS62368.1, , Design refer to GB 17945-2010 EAC TP TC 004 -20 ~ +60℃ (Refer to "Derating Curve") 20 ~ 95% RH non-condensing -30 ~ +85℃, 10 ~ 95% RH non-condensing ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3 ENVIRONMENT SAFETY & EMC (Note 4 & 5) PROTECTION WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH OUTPUT NUMBER 215*115*30mm (L*W*H) EMC IMMUNITY EMC EMISSION Parameter Parameter ESD Radiated EFT / Burst Surge Conducted Magnetic Field Conducted Radiated Harmonic Current Voltage Flicker DISCHARGE FUNCTION BATTERY FULL AC OK 2000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load 47 ~ 63Hz 86% 86.5% 8A/115VAC 4A/230VAC COLD START 60A/115VAC 60A/230VAC <0.5mA / 240VAC CH1:105 ~ 135% CH2:90 ~ 110% 21.5V±0.5V 32V±0.5V CH1:31 ~ 36V CH1:47 ~ 55V LAD-360B LAD-360C 27.6V CH2 41.5V CH2 27.6V CH1 41.5V CH1 1.5A(Battery Charger) 11.5A 7.14A 0 ~ 13A 0 ~ 8.64A 358.8W 358.56W -------- -------- 150mVp-p 240mVp-p CH1: 21.6 ~ 29V CH1: 32.4 ~ 43.5V -------- -------- -------- -------- -------- -------- ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (Default switch at 230VAC) 16ms/230VAC 12ms/115VAC at full load 86.5% 43V±0.5V CH1:59 ~ 69V LAD-360D 55.2V CH2 55.2V CH1 5.03A 0 ~ 6.53A 360.46W -------- 240mVp-p CH1: 43.5 ~ 58V -------- -------- -------- ±0.5% ±0.5% ±0.5% <100μA BATTERY STATIC DISCHARGE CURRENT OVER TEMPERATURE Standard Standard BS EN/EN55032 (CISPR32), EAC TP TC 020 BS EN/EN55032 (CISPR32), EAC TP TC 020 BS EN/EN61000-4-2 BS EN/EN61000-4-3 BS EN/EN61000-4-4 BS EN/EN61000-4-5 BS EN/EN61000-4-6 BS EN/EN61000-4-8 ----- ----- Test Level / Note Test Level / Note Level 3, 8KV air ; Level 2, 6KV contact; criteria A Level 3, 10V/m ; criteria A Level 3, 2KV ; criteria A Level 3, 1KV/Line-Line ;2KV/Line-FG ;criteria A Level 3, 10V ; criteria A Level 4, 30A/m ; criteria A Class A Class A ----- ----- ℃ μμ http://www.meanwell.com) ℃℃ ※ :https://www.meanwell.com/serviceDisclaimer.aspx BATTERY DISCONNECT/ REVERSE POLARITY BATTERY LOW File Name:LAD-360-SPEC 2022-10-14 OUTPUT INPUT MODEL Protection type : Shut down o/p voltage, re-power on to removed Protection type : Shut down o/p voltage, re-power on to removed 0.75Kg; 15pcs/12.25Kg/0.7CUFT Protection type : CH1 OLP, CH2 with battery: The unit will enter to UPS mode when CH1 is around 105%~120%, when total output of CH1 + CH2 reach around 125%~135% output shuts down CH1 OLP, CH2 without battery:Shut down o/p voltage,re-power on to removed CH2 : Constant current limiting; fault condition does not affect CH1 working,recovers automatically after fault condition is removed (External fuse is mandatory in series connection with battery for protection) BATTERY REVERSE POLARITY Protected when reverse polarity , , recovers automatically after fault condition is removed no damage -------- 1.5A(Battery Charger) -------- 1.5A(Battery Charger) -------- 360W Economical Security/Fire Alarm PSU with Battery Charger/UPS L A D - 3 6 0 series 1394.9K hrs min. Telcordia SR-332 (Bellcore); 153.3K hrs min. MIL-HDBK-217F (25℃) TTL signal, High / Open : ; Low : charge ; Ice : max. 30mA@ 50VDC Charge Dis TTL signal, High / Open : AC Fail ; Low : AC OK ; Ice : max. 30mA@ 50VDC TTL signal, High / Open : Battery charging ; Low : Battery full ; Ice : max. 30mA@ 50VDC TTL signal, High / Open : Battery connect/normal ; Low : Battery disconnect/reverse polarity; Ice : max. 30mA@ 50VDC TTL signal, High / Open : Battery normal ; Low : Battery low; Ice : max. 30mA@ 50VDC |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |