13 / 15 page ![]() H3CA H3CA 13 s CHECK INPUT ON-Delay Operation When a no-voltage input signal is applied to the timer during the lapse of a set time, the remaining set time will become 0 and the timer will enter the next control state. Also, while the Check Signal is applied, the elapsed time measurement of the set time is not performed. The Check input is especially useful where ON-delay override may be desirable. t - a = less than set time Reset 3 - 7 (X-B1) Power 2 - 10 (A1-A2) Start 3 - 6 (X-C1) Control 9 - 11 output NO (15-18) Check 3 - 4 (X-E1) Reset 3 - 7 (X-B1) Power 2 - 10 (A1-A2) Start 3 - 6 (X-C1) Control 9 - 11 output NO (15-18) Check 3 - 4 (X-E1) t + set time t - a = less than set time Repeat Cycle Operation The Check input signal in Repeat cycle mode allows the timer to be used like a binary flip-flop or alternating relay. Set an unattainable time, such as 999 hours. Apply the no-voltage Check input to shift output status from ON to OFF, or vice-versa. Jumper terminals 3 and 6 (X and C1) to short the start function. The Check input then controls the output relay like a flip-flop or alternating relay. This may be used to alternate wear on main and secondary equipment such as pumps. t-a Installation s PROPER INPUT CONNECTIONS (H3CA-A, H3CA-FA) The neutral or common of the power supply is connected to terminal 2 (A2) of the timer. Terminal 10 (A1) should be connected to the "hot" or positive of the power supply. Do not apply voltage to Check, Gate, Start and Reset inputs. These are no-voltage type inputs. ...... • • • Power supply AC or DC Input contact Load 2 (A2) 10 (A1) 8 9 11 • ↓ ↑ • 4, 5, 6, 7 C, G, S, R H3CA-A (H3CA-FA) s PROPER OUTPUT CONNECTIONS Design your control circuit using the output relay contacts to switch the load. Never switch a load with the contact that is being used as an input signal. The timer's circuitry may be damaged. s PARALLEL CONNECTIONS Parallel connection of two or more Omron Timers is possible as shown by the diagram to the right. This will allow the simultaneous start or restart of multiple timers using a single switch for the Start Input and a single switch for the Reset Input. It is possible to wire only up to 4 timers in this manner. Wiring more than 4 results in poor performance due to excessive voltage drop. Reset Start Com Com H3CA-A Timer H3CA-A Timer 10 11 9 1 2 3 4 5 6 7 8 10 11 9 1 2 3 4 5 6 7 8 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |