81 / 117 page ![]() ZSSC1750 / ZSSC1751 Datasheet © 2016 Integrated Device Technology, Inc. 81 April 20, 2016 The voltage accumulator is reset to 0 under these conditions: • On assertion of startAdcV (rising edge) in the FP State • At start of the first conversion in the LP or ULP State • Each time the result counter is reset (if the result counter is enabled) Note: The voltage accumulator functionality can be used to calculate the mean value of the voltage. After the last accumulation within an MRCS, the upper 16 bits of the voltage accumulator are compared to the voltage threshold adcVTh, which is interpreted as a signed value in this case. This comparison can be used to generate a “set interrupt” strobe for irqStat[9]; however, to enable the generation of the “set interrupt” strobe, bit VThWuEna in register adcAcmp must be set to 1. The “set interrupt” strobe is generated when • adcVTh is greater than 0 and adcVaccu is less than or equal to adcVTh • adcVTh is lower than 0 and adcVaccu is greater than or equal to adcVTh • adcVTh is equal to 0 and adcVaccu is equal to 0 Important: The threshold adcVTh is either interpreted as an unsigned or signed value depending on the operation mode (VThSel). Note: The voltage comparators compare only on the MSBs of the conversion result, so it might be beneficial to use the post-correction gain functionality to shift left the results to increase the accuracy of the comparison. 3.8.3.19 Register “adcVTh” – Voltage Threshold Value Table 3.46 Register adcVTh Name Address Bits Default Access Description adcVTh[7:0] 46HEX [7:0] 00HEX RW Voltage threshold. If VThSel == 0, then adcVTh is interpreted as an unsigned value and it is compared to the absolute value of a single voltage conversion. If VThSel == 1, then adcVTh is interpreted as a signed value and it is compared to the accumu- lated voltage conversion results at the end of an MRCS. adcVTh[15:8] 47HEX [7:0] 00HEX RW 3.8.3.20 Register “adcVaccu” – Voltage Accumulator Value Table 3.47 Register adcVaccu Name Address Bits Default Access Description adcVaccu[7:0] 10HEX [7:0] 00HEX RO Present voltage accumulator value adcVaccu[15:8] 11HEX [7:0] 00HEX RO adcVaccu[23:16] 12HEX [7:0] 00HEX RO |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |