6 / 16 page ![]() Ceragel CPS71D and CPS71 6 Endress+Hauser Installation Installation instructions • Electrode versions TB, TC and TP Do not install the electrodes upside down. The angle of inclination must be at least 15° from the horizontal. A smaller inclination angle is not permitted as it could cause an air bubble to form in the glass sphere and prevent the inner electrolyte from completely wetting the pH diaphragm. • Electrode version TU This electrode is suitable for upside-down installation. You can install it at any angle. NOTICE Before screwing in the electrode, make sure the assembly threaded connection is clean and runs smoothly. ‣ Screw in the electrode finger-tight (3 Nm)! (Data apply only if installing with Endress+HauserOPA assemblies.) ‣ Make sure to follow the installation instructions in the Operating Instructions of the used assembly. 15° 15° A B A0024316 2 Installation of electrode versions TB, TC, TP; installation angle at least 15° from the horizontal A Permitted orientation B Forbidden orientation 360° A0024597 3 Installation of electrode version TU; any installation angle Installation instructions for electrode version TP LCAUTION Sudden rupture and flying glass splinters from the glass electrode with pressurized reference (approx. 7 bar abs. internal pressure) ‣ Always wear protective goggles when working with these electrodes ‣ Be particularly careful when removing the silicone seal on the reference junction. Here, a knife is used to activate the electrode for measuring operation. Before commissioning the electrode, you must remove the silicone seal from the junction. The pH value can only be measured properly once the seal has been removed. To do this, proceed as follows: 1. Using the knife supplied, completely remove the silicone seal from the junction. 2. To ensure optimum accuracy with this as with all pH electrodes, place the electrode in a calibration standard buffer solution with a pH of between 4 and 9 for 15-20 minutes prior to calibration. 3. Put the electrode into operation. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |