363 / 429 page ![]() 363/429 10-BIT ANALOG TO DIGITAL CONVERTER (ADC) ANALOG TO DIGITAL CONVERTER (Cont’d) Single and continuous conversion modes are available. These two modes may be triggered by an external signal or, internally, by the Multifunc- tion Timer MFT0. A Power-Down programmable bit allows the ADC to be set in low-power idle mode. The reference voltage AVDD can be switched off when the ADC is in power down mode. The ADC Interrupt Unit provides two maskable channels (Analog Watchdog and End of Conver- sion) with hardware fixed priority, and up to 7 pro- grammable priority levels. Conversion Time The maximum CKAD frequency allowable for the analog part is 4 MHz. This is provided by a pro- grammable prescaler that divides the ST9 system clock (INTCLK) and a divider by 2. The user must program the PR[2:0] bits in Control Logic Register 2 (CLR2, R253 - Page 63) to select the right pres- caler dividing factor to obtain the correct clock fre- quency for the analog part. Table 69 shows the possible prescaling values and the related sam- pling and conversion times. Generally, the formu- las for the sampling and conversion times are: TSample = (TINTCLK x 2) x (PR[2:0] x 8) TConv = (TINTCLK x 2) x (PR[2:0] x 28) The user may need to increase the conversion time if a resistor is added to the input pin, for in- stance, as an overvoltage protection. In this case, the ADC needs a longer sampling time to work correctly. CAUTION: ADC INPUT PIN CONFIGURATION The input Analog channel is selected by using the I/O pin Alternate Function setting (PxC2, PxC1, PxC0 = 1,1,1) as described in the I/O ports sec- tion. The I/O configuration of the port connected to the ADC converter is modified in order to prevent the analog voltage present on the I/O pin from causing high power dissipation across the input buffer. Analog channels should be maintained in Alternate Function configuration for this reason. 10.11.3 Functional Description 10.11.3.1 Operating Modes Two operating modes are available: Continuous Mode and Single Mode. To enter one of these modes it is necessary to program the CONT bit of the Control Logic Register2 (CLR2, R253- page63). The Continuous Mode is selected when CONT is set, while Single Mode is selected when CONT is reset. Both modes operate in AUTOSCAN configuration, allowing sequential conversion of the input chan- nels. The number of analog inputs to be converted may be set by software, by setting the number of the first channel to be converted into Control Reg- ister 1 (SC[3:0] bits). As each conversion is com- pleted, the channel number is automatically incre- mented, up to channel 15. For example, if SC[3:0] are set to 0011, the conversion will proceed from channel 3 to channel 15, whereas, if SC[3:0] are set to 1111, only channel 15 will be converted. When the ST bit of Control Logic Register 2 is set, either by software or by hardware (by an internal or external synchronisation trigger signal), the an- alog inputs are sequentially converted (from the first selected channel up to channel 15) and the re- sults are stored in the relevant pair of Data Regis- ters. In Single Mode (CONT = “0”), the ST bit is reset by hardware following conversion of channel 15; an End of Conversion (ECV) interrupt request is is- sued and the ADC waits for a new start event. In Continuous Mode (CONT = “1”), a continuous conversion flow is initiated by the start event. When conversion of channel 15 is complete, conversion of channel 's' is initiated (where 's' is specified by the setting of the SC[3:0] bits); this will continue until the ST bit is reset by software. In all cases, an ECV interrupt is issued each time channel 15 conversion ends. When channel 'i' is converted ('s' <'i' <15), the re- lated pair of Data Registers is reloaded with the new conversion result and the previous value is lost. The End of Conversion (ECV) interrupt serv- ice routine can be used to save the current values before a new conversion sequence (so as to cre- ate signal sample tables in the Register File or in Memory). 10.11.3.2 Triggering and Synchronisation In both modes, conversion may be triggered by in- ternal or external conditions; externally this may be tied to EXTRG, as an Alternate Function input on an I/O port pin, and internally, it may be tied to INTRG, generated by a Multifunction Timer pe- ripheral. Both external and internal events can be separately masked by programming the EXTG/ INTG bits of the Control Logic Register (CLR). The events are internally ORed, thus avoiding potential hardware conflicts. However, the correct proce- dure is to enable only one alternate synchronisa- tion condition at any time. 9 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |