| Electronic Components Datasheet Search |
|
ST92F124 Datasheet(PDF) 364 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST92F124 Datasheet(HTML) 364 Page - STMicroelectronics |
|
364 / 429 page ![]() 364/429 10-BIT ANALOG TO DIGITAL CONVERTER (ADC) ANALOG TO DIGITAL CONVERTER (Cont’d) The effect of either of these synchronisation modes is to set the ST bit by hardware. This bit is reset, in Single Mode only, at the end of each group of conversions. In Continuous Mode, all trig- ger pulses after the first are ignored. The synchronisation sources must be at a logic low level for at least the duration of two INTCLK cycles and, in Single Mode, the period between trigger pulses must be greater than the total time required for a group of conversions. If a trigger oc- curs when the ST bit is still set, i.e. when a conver- sion is still in progress, it will be ignored. Note: The external trigger will set the CLR2.ST bit even if the CLR2.POW is reset. 10.11.3.3 Analog Watchdog Two internal Analog Watchdogs are available for highly flexible automatic threshold monitoring of external analog signal levels. Depending on the value of the CC[3:0] bits in Control Logic Register1 these two watchdog are mapped onto 2 of the 16 available adjacent channels, allowing the user to set the channel to be monitored. Refer to Table 68 to see the possible choices for this feature. Analog watchdog channels (named as A and B) monitor an acceptable voltage level window for the converted analog inputs. The external voltages applied to inputs A and B are considered normal while they remain below their respective Upper thresholds, and above or at their respective Lower thresholds. When the external signal voltage level is greater than, or equal to, the upper programmed voltage limit, or when it is less than the lower programmed voltage limit, a maskable interrupt request is gen- erated and the Compare Results Register is up- dated in order to flag the threshold (Upper or Low- er) and channel (A or B) responsible for the inter- rupt. The four threshold voltages are user pro- grammable in dedicated registers pairs (R244 to R251, page 63). Only the 4 MSBs of the Compare Results Register are used as flags, each of the four MSBs being associated with a threshold con- dition. Following a reset, these flags are reset. During normal ADC operation, the CRR bits are set, in or- der to flag an out of range condition and are auto- matically reset by hardware after a software reset of the Analog Watchdog Request flag in the ICR Register. 10.11.3.4 Power Down Mode Before enabling an ADC conversion, the POW bit of the Control Logic Register must be set; this must be done at least 10 µs before the first conver- sion start, in order to correctly bias the analog sec- tion of the converter circuitry. When the ADC is not required, the POW bit may be reset in order to reduce the total power con- sumption. This is the reset configuration, and this state is also selected automatically when the ST9 is placed in Halt Mode (following the execution of the halt instruction). Figure 156. Analog Watchdog Function Figure 157. ADC Trigger Source Analog Voltage Upper Threshold Lower Threshold Normal Area (Window Guarded) Ext. Trigger Enable ADC Trigger Int. Trigger Enable On-Chip Event Software Trigger Start group of conversions Continuous or Single mode EXTRG MFT0 9 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |