  SA5775AD Datasheet HTML 1Page - NXP Semiconductors SA5775AD Datasheet HTML 2Page - NXP Semiconductors SA5775AD Datasheet HTML 3Page - NXP Semiconductors SA5775AD Datasheet HTML 4Page - NXP Semiconductors SA5775AD Datasheet HTML 5Page - NXP Semiconductors SA5775AD Datasheet HTML 6Page - NXP Semiconductors SA5775AD Datasheet HTML 7Page - NXP Semiconductors SA5775AD Datasheet HTML 8Page - NXP Semiconductors SA5775AD Datasheet HTML 9Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 10 page
background image
Philips Semiconductors
Product specification
SA5775A
Differential air-core meter driver
1999 Sep 20
3
BLOCK DIAGRAM
8
9
10
12
13
14
15
16
1
2
3
4
57
6
3
LOGIC
DAC
MUX
SHUT–DOWN
LOGIC
11
SL00454
Figure 2. Block diagram
Table 1.
SA5775A Pin Descriptions for the N Package (Dual In-Line)
Pin #
Name
Function
1.
SIN–
Negative output connection to the SIN coil of the gauge.
2.
SIN+
Positive output connection to the SIN coil of the gauge.
3.
AGND
Ground for VIGN supply. Pins 3, 13 and 14 connected on the circuit board.
4.
VBB
Analog supply. Nominally 14.0 V.
5.
DATAOUT Serial data output. Output of the internal shift register. When a new data word is shifted in, the old word is shifted out the
DATAOUT pin.
6.
DATAIN
Serial data input. A new data word is serially shifted into the part on the rising edge of SCLK. The data is shifted in MSB first.
7.
VCC
5 V logic supply. The internal latches and registers are set to zero on the rising edge of this signal.
8.
OE
Output drivers are turned off when this input is low. Current draw is minimized.
9.
SCLK
Serial clock input. Data is loaded into the part on the rising edge of SCLK.
10.
CS
Active high chip select input. When CS is high, the part is enabled to receive a new serial input word. The high-to-low tran-
sition of CS loads the new 10-bit word into the DAC registers and updates the output.
11.
ST
Status output from this IC to indicate that the outputs have been disabled. The outputs may be disabled due to shorted out-
puts, over temperature conditions, power up reset, or output enable control pin .This output is an open drain output .Multiple
status outputs may be wire OR’ed together .This output is low when the outputs are disabled due to a fault condition.
12.
nc
Not connected
13.
DGND
Ground for VCC supply. Connect to Pins 3 and 14.
14.
AGND
Ground for VBB supply. Connect to Pins 3 and 13.
15.
COS–
Negative output connection to the COS coil of the gauge.
16.
COS+
Positive output connection to the COS coil of the gauge.



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com