Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

AMC1100DWVR Datasheet(PDF) 6 Page - Texas Instruments

Part # AMC1100DWVR
Description  AMC1100 Fully-Differential Isolation Amplifier
PDF  38 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI2 [Texas Instruments]
Direct Link  https://www.ti.com
Logo TI2 - Texas Instruments

AMC1100DWVR Datasheet(HTML) 6 Page - Texas Instruments

Back Button AMC1100DWVR Datasheet HTML 2Page - Texas Instruments AMC1100DWVR Datasheet HTML 3Page - Texas Instruments AMC1100DWVR Datasheet HTML 4Page - Texas Instruments AMC1100DWVR Datasheet HTML 5Page - Texas Instruments AMC1100DWVR Datasheet HTML 6Page - Texas Instruments AMC1100DWVR Datasheet HTML 7Page - Texas Instruments AMC1100DWVR Datasheet HTML 8Page - Texas Instruments AMC1100DWVR Datasheet HTML 9Page - Texas Instruments AMC1100DWVR Datasheet HTML 10Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 38 page
background image
6
AMC1100
SBAS562B – APRIL 2012 – REVISED DECEMBER 2019
www.ti.com
Product Folder Links: AMC1100
Submit Documentation Feedback
Copyright © 2012–2019, Texas Instruments Incorporated
6.7 Safety-Related Certifications
VDE
UL
CSA
Certified according to
DIN VDE V 0884-11: 2017-01 and
DIN EN 61010-1 (VDE 0411-1) : 2011-07
Recognized under 1577 component
recognition program
Recognized under CSA component
acceptance NO 5 program, IEC 60950-1,
and IEC 61010-1
Basic insulation
Single protection
Basic insulation
Certificate number: 40047657
File number: E181974
Certificate number: 2643952
(1)
The maximum safety temperature, TS, has the same value as the maximum junction temperature, TJ, specified for the device. The IS
and PS parameters represent the safety current and safety power, respectively. Do not exceed the maximum limits of IS and PS. These
limits vary with the ambient temperature, TA.
The junction-to-air thermal resistance, RθJA, in the Thermal Information table is that of a device installed on a high-K test board for
leaded surface-mount packages. Use these equations to calculate the value for each parameter:
TJ = TA + RθJA × P, where P is the power dissipated in the device.
TJ(max) = TS = TA + RθJA × PS, where TJ(max) is the maximum junction temperature.
PS = IS × VDD1max + IS × VDD2max, where VDD1max is the maximum high-side supply voltage and VDD2max is the maximum low-side
supply voltage.
6.8 Safety Limiting Values
Safety limiting intends to minimize potential damage to the isolation barrier upon failure of input or output circuitry.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
IS
Safety input, output,
or supply current
DUB package, RθJA = 75.1°C/W, TJ = 150°C, TA = 25°C,
VDD1 = VDD2 = 5.5 V, see Figure 1
302
mA
DWV package, RθJA =102.8°C/W, TJ = 150°C, TA = 25°C,
VDD1 = VDD2 = 5.5 V, see Figure 1
221
PS
Safety input, output,
or total power(1)
DUB package, RθJA = 75.1°C/W, TJ = 150°C, TA = 25°C,
see Figure 2
1664
mW
DWV package, RθJA = 102.8°C/W, TJ = 150°C,
TA = 25°C, see Figure 2
1216
mW
TS
Maximum safety temperature
150
°C



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com