S25FL512SDPBFAQ13 Datasheet(PDF) 104 Page - Infineon Technologies AG

Part # S25FL512SDPBFAQ13
Description  512 Mb (64 MB) FL-S Flash
PDF  167 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  INFINEON [Infineon Technologies AG]
Direct Link  http://www.infineon.com
Logo INFINEON - Infineon Technologies AG

S25FL512SDPBFAQ13 Datasheet(HTML) 104 Page - Infineon Technologies AG

Back Button S25FL512SDPBFAQ13 Datasheet HTML 100Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 101Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 102Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 103Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 104Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 105Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 106Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 107Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 108Page - Infineon Technologies AG Next Button
Zoom Inzoom in Zoom Outzoom out
 104 / 167 page
background image
Datasheet
104
001-98284 Rev. *T
2023-08-30
512 Mb (64 MB) FL-S Flash
SPI Multi-I/O, 3.0 V
Commands
9.4.7
DDR fast read (DDRFR 0Dh, 4DDRFR 0Eh)
The instruction
• 0Dh (ExtAdd = 0) is followed by a 3-byte address (A23–A0) or
• 0Dh (ExtAdd = 1) is followed by a 4-byte address (A31–A0) or
•0Eh is followed by a 4-byte address (A31–A0)
The DDR Fast Read command improves throughput by transferring address and data on both the falling and
rising edge of SCK. It is similar to the Fast Read command but allows transfer of address and data on every edge
of the clock.
The maximum operating clock frequency for DDR Fast Read command is 80 MHz.
For the DDR Fast Read command, there is a latency required after the last address bits are shifted into SI before
data begins shifting out of SO. There are different ordering part numbers that select the latency code table used
for this command, either the High Performance LC (HPLC) table or the Enhanced High Performance LC (EHPLC)
table. The HPLC table does not provide cycles for mode bits so each DDR Fast Read command starts with the 8-bit
instruction, followed by address, followed by a latency period.
This latency period (dummy cycles) allows the device internal circuitry enough time to access data at the initial
address. During the dummy cycles, the data value on SI is “don’t care” and may be high impedance. The number
of dummy cycles is determined by the frequency of SCK (see Table 24). The number of dummy cycles is set by
the LC bits in the Configuration Register (CR1).
Then the memory contents, at the address given, is shifted out, in DDR fashion, one bit at a time on each clock
edge through SO. Each bit is shifted out at the SCK frequency by the rising and falling edge of the SCK signal.
The address can start at any byte location of the memory array. The address is automatically incremented to the
next higher address in sequential order after each byte of data is shifted out. The entire memory can therefore
be read out with one single read instruction and address 000000h provided. When the highest address is reached,
the address counter will wrap around and roll back to 000000h, allowing the read sequence to be continued
indefinitely.
The EHPLC table does provide cycles for mode bits so a series of DDR Fast Read commands may eliminate the
8-bit instruction after the first DDR Fast Read command sends a mode bit pattern of complementary first and
second Nibbles, e.g. A5h, 5Ah, 0Fh, etc., that indicates the following command will also be a DDR Fast Read
command. The first DDR Fast Read command in a series starts with the 8-bit instruction, followed by address,
followed by four cycles of mode bits, followed by a latency period. If the mode bit pattern is complementary the
next command is assumed to be an additional DDR Fast Read command that does not provide instruction bits.
That command starts with address, followed by mode bits, followed by latency.
When the EHPLC table is used, address jumps can be done without the need for additional DDR Fast Read
instructions. This is controlled through the setting of the Mode bits (after the address sequence, as shown in
Figure 89 and Figure 88. This added feature removes the need for the eight bit SDR instruction sequence to
reduce initial access time (improves XIP performance). The Mode bits control the length of the next DDR Fast Read
operation through the inclusion or exclusion of the first byte instruction code. If the upper nibble (I/O[7:4]) and
lower nibble (I/O[3:0]) of the Mode bits are complementary (i.e. 5h and Ah) then the next address can be entered
(after CS# is raised HIGH and then asserted LOW) without requiring the 0Dh or 0Eh instruction, as shown in
Figure 89, thus, eliminating eight cycles from the command sequence. The following sequences will release the
device from this continuous DDR Fast Read mode; after which, the device can accept standard SPI commands:
1. During the DDR Fast Read Command Sequence, if the Mode bits are not complementary the next time CS# is
raised HIGH the device will be released from the continuous DDR Fast Read mode.
2. During any operation, if CS# toggles HIGH to LOW to HIGH for eight cycles (or less) and data input (SI) are not
set for a valid instruction sequence, then the device will be released from DDR Fast Read mode.
CS# should not be driven HIGH during mode or dummy bits as this may make the mode bits indeterminate.
The HOLD function is not valid during any part of a Fast DDR Command.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com