S25FL512SDPBFAQ13 Datasheet(PDF) 105 Page - Infineon Technologies AG

Part # S25FL512SDPBFAQ13
Description  512 Mb (64 MB) FL-S Flash
PDF  167 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  INFINEON [Infineon Technologies AG]
Direct Link  http://www.infineon.com
Logo INFINEON - Infineon Technologies AG

S25FL512SDPBFAQ13 Datasheet(HTML) 105 Page - Infineon Technologies AG

Back Button S25FL512SDPBFAQ13 Datasheet HTML 101Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 102Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 103Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 104Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 105Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 106Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 107Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 108Page - Infineon Technologies AG S25FL512SDPBFAQ13 Datasheet HTML 109Page - Infineon Technologies AG Next Button
Zoom Inzoom in Zoom Outzoom out
 105 / 167 page
background image
Datasheet
105
001-98284 Rev. *T
2023-08-30
512 Mb (64 MB) FL-S Flash
SPI Multi-I/O, 3.0 V
Commands
Although the data learning pattern (DLP) is programmable, the following example shows example of the DLP of
34h. The DLP 34h (or 00110100) will be driven on each of the active outputs (i.e. all four I/Os on a x4 device, both
I/Os on a x2 device and the single SO output on a x1 device). This pattern was chosen to cover both DC and AC
data transition scenarios. The two DC transition scenarios include data low for a long period of time (two half
clocks) followed by a high going transition (001) and the complementary low going transition (110). The two AC
transition scenarios include data low for a short period of time (one half clock) followed by a high going transition
(101) and the complementary low going transition (010). The DC transitions will typically occur with a starting
point closer to the supply rail than the AC transitions that may not have fully settled to their steady state (DC)
levels. In many cases the DC transitions will bound the beginning of the data valid period and the AC transitions
will bound the ending of the data valid period. These transitions will allow the host controller to identify the
beginning and ending of the valid data eye. Once the data eye has been characterized the optimal data capture
point can be chosen. See “SPI DDR data learning registers” on page 69 for more details.
Figure 86
DDR fast read initial access (3-byte address, 0Dh [ExtAdd = 0, EHPLC = 11b])
Figure 87
Continuous DDR fast read subsequent access (3-byte address [ExtAdd = 0, EHPLC = 11b])
Figure 88
DDR fast read initial access (4-byte address, 0Eh or 0Dh [ExtAdd = 1], EHPLC = 01b)[47]
Figure 89
Continuous DDR fast read subsequent access (4-byte address [ExtAdd = 1], EHPLC = 01b)[47]
CS#
SCK
SI
SO
Phase
7
6
5
4
3
2
1
0
23 22
0 7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0 7 6
5 4 3 2 1 0
Instruction
Address
Mode
Dummy
Data 1
Data 2
CS#
SCK
IO0
IO1
Phase
23
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
Address
Mode
Dum
Data 1
D2
CS#
SCK
SI
SO
Phase
7
6
5
4
3
2
1
0
31
1 0 7 6 5 4 3 2 1 0
7 6
5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6
Instruction
Address
Mode
DLP
Data 1
D2
CS#
SCK
SI
SO
Phase
31
1 0
7 6
5 4
3 2
1 0
7 6
5 4
3 2 1 0
7
6 5
4 3
2 1
0 7
6
Address
Mode
DLP
Data 1
D2
Note
47.Example DLP of 34h (or 00110100).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com