Back Button OPA2197IDRG4 Datasheet HTML 25Page - Texas Instruments OPA2197IDRG4 Datasheet HTML 26Page - Texas Instruments OPA2197IDRG4 Datasheet HTML 27Page - Texas Instruments OPA2197IDRG4 Datasheet HTML 28Page - Texas Instruments OPA2197IDRG4 Datasheet HTML 29Page - Texas Instruments OPA2197IDRG4 Datasheet HTML 30Page - Texas Instruments OPA2197IDRG4 Datasheet HTML 31Page - Texas Instruments OPA2197IDRG4 Datasheet HTML 32Page - Texas Instruments OPA2197IDRG4 Datasheet HTML 33Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 56 page
background image
VCC
VEE
R2
1.6
0Ÿ
VOUT
V+
VIN
RL
10
NŸ
R1
1.69
NŸ
C1
470 nF
Op Amp Gain Stage
Slew Rate Limiter
-
+
OPA197
VCC
VEE
V+
-
+
OPA197
29
OPA197, OPA2197, OPA4197
www.ti.com
SBOS737C – JANUARY 2016 – REVISED MARCH 2018
Product Folder Links: OPA197 OPA2197 OPA4197
Submit Documentation Feedback
Copyright © 2016–2018, Texas Instruments Incorporated
8.2.2 Slew Rate Limit for Input Protection
In control systems for valves or motors, abrupt changes in voltages or currents can cause mechanical damages.
By controlling the slew rate of the command voltages into the drive circuits, the load voltages ramps up and down
at a safe rate. For symmetrical slew-rate applications (positive slew rate equals negative slew rate), one
additional op amp provides slew-rate control for a given analog gain stage. The unique input protection and high
output current and slew rate of the OPAx197 make the device an optimal amplifier to achieve slew rate control
for both dual- and single-supply systems.Figure 55 shows the OPA197 in a slew-rate limit design.
Figure 55. Slew Rate Limiter Uses One Op Amp
For step-by-step design procedure, circuit schematics, bill of materials, PCB files, simulation results, and test
results, refer to TI Precision Design TIDU026, Slew Rate Limiter Uses One Op Amp.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com