| Electronic Components Datasheet Search |
|
LD155 Datasheet(PDF) 10 Page - LightGraphix |
|
|
|||||||||||||||||||||||||||||
LD155 Datasheet(HTML) 10 Page - LightGraphix |
|
10 / 11 page ![]() LD155 T: +44 (0)1322 527 629 E: light@lightgraphix.co.uk www.lightgraphix.co.uk Page 10 of 11 | Data sheet issued: 22 May 2026 Installation requirements can vary but the minimum installation volume requirements must be adhered to. The volume of air or concrete is to ensure that the thermal perfomance of the product is not comprimised and ensures the proper cooling of the LED. The minimum recess depth is 85mm. The volumes below are presented as L x W x H. E3/F1 LED Output current Minimum void dimension requirements (Lmm x Wmm x Hmm) Minimum volume of concrete cm³ Litre(s) LD155-E3-350 300 x 300 x 180 18000cm³ 18 LD155-E3-500 LD155-E3-700 400 x 400 x 200 32000cm³ 32 N1 LED Output current Minimum void dimension requirements (Lmm x Wmm x Hmm) Minimum volume of concrete cm³ Litre(s) LD155-N1-350 300 x 300 x 180 18000cm³ 18 LD155-N1-500 LD155-N1-700 400 x 400 x 200 32000cm³ 32 E3/F1 LED Output current Minimum void dimension requirements (Lmm x Wmm x Hmm) Minimum void volume cm³ Litre(s) LD155-E3-350 120 x 120 x 85 1,200cm³ 1.2 LD155-E3-500 160 x 160 x 85 2,200cm³ 2.2 LD155-E3-700 220 x 220 x 85 4,000cm³ 4.0 N1 LED Output current Minimum void dimension requirements (Lmm x Wmm x Hmm) Minimum void volume cm³ Litre(s) LD155-N1-350 150 x 150 x 85 1,900cm³ 1.9 LD155-N1-500 180 x 180 x 85 2,700cm³ 2.7 LD155-N1-700* 240 x 240 x 85 4,900cm³ 4.9 * Max 25 °C ambient W L H INSTALLATION REQUIREMENTS H W L Mounting in surface with air void underneath - /SC Spring Clip and /485S Sleeve If installing into a surface where there will be air around the base of the fitting, these are the minimum space requirements around the fixture. For example, a floating floor. The fixture can be installed into a solid floor but the minimum air volume requirements need to be adhered to. Mounting into solid concrete with the 485N Concrete Housing Concrete is great for absorbing heat so the LD155 with the concrete housing performs excellently. The below figures detail the minimum volume of concrete that should be used around the housing. This is not an issue if installed into a concrete floor, but can be if the housing is being used in lawn or soil applications where the housing is fixed at the base with a small amount of concrete. LD155-F1 /MSB /WB /WWB /OB A Distance from the centre of the fitting to the lit surface 125mm B Spacing for an even wash 350mm 400mm 500mm 500mm C 700mA Lit distance 5m 4m 2m 4m |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |