26 / 50 page ![]() Rev. A | Page 26 of 50 | August 2007 ADSP-21990 Programmable Flags Cycle Timing Table 7 and Figure 8 describe programmable flag operations. Table 7. Programmable Flags Cycle Timing Parameter Min Max Unit Timing Requirement tHFI Flag Input Hold Is Asynchronous 3 ns Switching Characteristics tDFO Flag Output Delay with Respect to CLKOUT 7 ns tHFO Flag Output Hold After CLKOUT High 6 ns Figure 8. Programmable Flags Cycle Timing tDFO PF (INPUT) tHFI PF (OUTPUT) CLKOUT FLAG INPUT FLAG OUTPUT tHFO |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|